~ 4 ~

 

ET-485  

NOVATEK-ELECTRO

 

Terms and abbreviations 

 

10Base-T 

 Ethernet standard for twisted pair communication with the speed of 10Mbit/s;

 

 

100Base-T 

 Ethernet standard for twisted pair communication with the speed of 100Mbit/s;

 

 

8P8C/RJ45 

 is an unified socket for 10Base-T / 100Base-T network connections; 

 

Twisted pair

 

 is a pair of insulated conductors inside the cable, which are twisted together in order to reduce the distortion of the transmitted 

signal;

 

 

Indicator

 – is a LED element; 

 

Client 

 is a device, which is addressing the other devices (server) with a request to perform certain functions;

 

 

Package 

 is a block of data to be transmitted between devices; 

 

Unit 

 is the ЕТ-485 Protocol converter; 

 

Server 

 is a unit, which performs specific functions at the request of other units; 

 

ASCII 

 is a table of standard codes for information interchange; 

 

 

Ethernet 

 is a standard for packet network communication and transmitting data between units (e.g., PCs); 

 

HTTP 

 is a protocol for transferring Web-pages and other data over "client-server " technology;

 

 

Internet 

 is a global routing system of units for storing and transferring data;

 

 

IP (protocol) 

 is a routable protocol for transferring data over Ethernet. It is a part of TCP/IP and used for Internet;

  

 

IP (address) 

 is a node address, which is unique within a single network, operating over the IP protocol;

 

 

IPv4 

 is a four byte IP-address;

 

 

MAC (address) 

 is an address, used for device authentication during Ethernet transmissions. It is usually unique although qualified personnel can 

change it under certain circumstances.

 

 

MAC-48 

 is a six byte MAC-address;

 

 

Modbus

 – is a standard and protocol for packet communication over the "client-server " technology for industrial electronic units; 

 

Modbus RTU 

 is a communication protocol of the unit for bite wise transfer of the package;  

 

Modbus ASCII 

 is a communication protocol of the unit for the transfer of package in the form of ASCII-symbols;  

 

Modbus TCP

 – is a protocol for transferring Modbus packages under the TCP/IP standard; 

 

RS-485/EIA-485 

 is a network standard for communicating units over the twisted pair;

 

 

TCP/IP 

 is a standard and a set of protocols for transferring data along the networks with delivery verification;

 

 

WEB 

 is a system for accessing documents on the server, used in the Internet.

 

 

WEB-page 

 is a document, file, recourse, which is available on the Web-server;

 

 

WEB-browser 

 is a WEB-server client for accessing the WEB-pages, which is primarily using the HTTP protocol.

 

Содержание ET- 485

Страница 1: ...NOVATEK ELECTRO LTD Intelligent Industrial Electronics Protocol converter Modbus RTU ASCII RS 485 to Modbus TCP Ethernet 485 USER MANUAL TECHNICAL DATA SHEET www novatek electro in...

Страница 2: ...ricity mains Do not use abrasives or organic compounds alcohol gasoline solvents etc for cleaning DO NOT OPEN AND REPAIR THE EQUIPMENT YOURSELF It may contain energized parts DO NOT OPERATE THIS UNIT...

Страница 3: ...the 485 12 6 Operating the 485 13 6 1 General information 13 6 2 Operating 485 over the HTTP protocol 13 6 3 Operating 485 over the Modbus TCP protocol 13 7 Settings 14 7 1 General information 14 7 2...

Страница 4: ...is a routable protocol for transferring data over Ethernet It is a part of TCP IP and used for Internet IP address is a node address which is unique within a single network operating over the IP proto...

Страница 5: ...bus requests from the clients to the units in the Modbus network and returns their answers to the clients 485 has flexible addressing within the Ethernet network overloading MAC address static and dyn...

Страница 6: ...ted pair Supported Ethernet protocols Modbus TCP HTTP Maximum number of connections over the Modbus TCP protocol 11 Integrated servers Modbus server HTTP server Data Exchange Interface over the Modbus...

Страница 7: ...y II Rated insulation voltage V 450 Rated impulse withstand voltage kV 2 5 Operating position arbitrary Pollutants in the amount which is not to exceed the maximum permissible concentration none 2 2 O...

Страница 8: ...1 Structure 3 1 1 Design The unit has a standard plastic case which can be attached to the DIN rails with the width of 35 mm The unit drawing together with the overall and setting dimensions is provi...

Страница 9: ...ecture provides data routing between the Modbus RTU ASCII RS 485 network and Ethernet 10base T 100base T network The operating speed and availability of channels for direct access to the memory allows...

Страница 10: ...is provided with a globally unique MAC address during the production and can be connected to local networks with a protected access to Internet Figure 4 Structural diagram of the unit DC power Process...

Страница 11: ...tc in the air 4 1 5 Switching adjustment and maintenance of the unit should be conducted by the qualified personnel who is familiar with the provisions of this user manual 4 2 6 The following regulati...

Страница 12: ...d signal while contact B is used for the inverted signal 2 Switch the cable connection with Ethernet network supplied to the Ethernet socket and Ethernet network Any connection peculiarities depending...

Страница 13: ...connection to an Ethernet network using the HTTP protocol on port 80 PC connection can be established using the WEB browser When a client connects to port 80 the unit starts expecting requests for HTM...

Страница 14: ...provides a response to the client If the request is addressed to another unit the unit sends the request into the Modbus network and waits for a response from a unit on the network RS 485 indicator is...

Страница 15: ...l Collection Description Access Address Acting settings Current unit configuration In any mode read only 200 262 Saved settings The collection is saved regardless of power supply and further used as t...

Страница 16: ...String of characters 0 Configuration mode is available upon entering the valid password 100 119 Control command 0 3 writing in the configuration mode 0 0 no activity 1 Restart unit restart 2 Save save...

Страница 17: ...hole period of operation 140 Table 7 Unit configuration settings Parameter Min Max Factory setting Description Address Addressing in the Ethernet network Static IP address IP address 192 168 0 111 IP...

Страница 18: ...ernet network 515 520 Switching to Ethernet network Connection port for Modbus TCP 1 65535 502 Used in case of TCP connection to the unit via Ethernet to exchange data over Modbus TCP protocol 521 IP...

Страница 19: ...odbus TCP connection 0 1 0 0 Modbus TCP connection is maintained regardless of the connection hold time 1 if all connections to Modbus TCP are busy the new client requesting for a connection can be co...

Страница 20: ...the odd even check to verify odds 0 1 0 Used in case of data exchange between the units in Modbus network if odd even check is enabled The same value for all units in Modbus network 0 Parity check 1...

Страница 21: ...de Waiting for a response is terminated if the subsequent byte of the response has not been received within the given time as indicated for the reception of response Waiting time shall not be less the...

Страница 22: ...d is correct you shall be granted access to the setup mode Settings page appears with a list of parameters detailed in Table 7 If the password is incorrect the password request shall be displayed once...

Страница 23: ...see Table 5 before setting parameters Factory set password is 11111 i e write 49 ASCII code for one to record the factory set password to registers 0 4 If the password is correct the mode register se...

Страница 24: ...the expiry of the service life 9 2 Guaranteed storage life is 3 years 9 3 Warranty period is 36 moth from the date of sale The manufacturer shall provide a free repair of the unit within the warranty...

Страница 25: ...ipping box should be stored indoors at a temperature of 45 to 70C and relative humidity of no more than 80 with no vapors available in the air capable of producing harmful effect on the shipping box a...

Страница 26: ...D C 30 Patparganj Industrial Area 1st flr Delhi 110092 INDIA Tel 91 11 42143253 Tel Fax 91 11 43010600 Email info novatek electro in Web www novatek electro in _____________________________ __________...

Страница 27: ...Proper communication between units of a subnet is possible under several conditions 1 All units of a subnet have similar mask Most of small LANs are using 255 255 255 0 mask 2 Mask starts with a group...

Страница 28: ...irst three bytes of the IP address which are different from those specified in Table A 1 or the ET 485 factory IP address is already taken the configurable unit should be temporarily removed from the...

Страница 29: ...administrator 2 Click the icon of the connection with the right button and select Properties in the drop down menu The Properties window opens see Fig A 3 3 Select Internet Protocol TCP IP from the li...

Страница 30: ...30 ET 485 NOVATEK ELECTRO Figure 3 Connection properties window in Windows OS Figure 3 TCP IP properties window in Windows OS...

Страница 31: ...ection or acquire it from your ISP Connect the unit directly to the PC and change the parameters Enable manual MAC address and Manually set MAC address to have the manual MAC address enabled and value...

Страница 32: ...s shall be only available to a given client using a given protocol In case of no requests from the client over the long period the access returns to locked mode Note The setup mode is provided over an...

Страница 33: ...50 2 66 B 82 R 98 b 114 r 35 51 3 67 C 83 S 99 c 115 s 36 52 4 68 D 84 T 100 D 116 t 37 53 5 69 E 85 U 101 e 117 u 38 54 6 70 F 86 V 102 f 118 v 39 55 7 71 G 87 W 103 g 119 w 40 56 8 72 H 88 X 104 h...

Отзывы: