123-1016-004
23
TROUBLESHOOTING GUIDE
Problem
Possible Cause
Solution
Excessive vibration.
1.
Work piece is not secure or held tightly
enough.
2.
Drill press incorrectly bolted to base.
3.
Non-stock stand or bench is not well
constructed, too light, or not level on
the floor. Make sure stand is solidly
constructed. Use sandbags to weigh
down the stand.
4.
Drill piece is blunt or damaged.
5.
Incorrect speed setting.
1.
Check work piece mounting.
Display screen shows
Press “OFF” button. Switch off computer by
master switch, wait one minute, and switch on
again. Check that the spindle index is not
engaged or if something is preventing the
spindle from turning. Note leaving the spindle
index unit in will not harm the motor; however,
it will put some strain on the index unit. It is
likely that the spindle index will be left in from
time to time, but the motor is designed for this.
The optical sensors that give the spindle position
feedback (‘Rotor Position’ State) are obscured,
damaged or have been disconnected. Dust over
a long period of time may have settled on the
sensors.
First, spin the spindle by hand to create a
draught through the sensors. Re-try the motor. If
the error remains, with the power switched off
and disconnected, remove the upper-rear guard
and remove any wood dust with a vacuum
cleaner. Avoid getting the nozzle too close to the
electronics. After this step, dust may fall into the
Headstock, so suck the dust out through the
vent at the front of the Headstock under the
spindle. Do this sequence a few times. Try
blowing if available with Vacuum or Air gun.
Replace guard.
Display screen shows
The computer has built in voltage condition and
temperature sensors. If this message appears,
check the temperature of the lower section of
the headstock. If it is very hot, switch off the
master switch and leave the machine to cool
down for a period. If the headstock is relatively
cool, the computer may have detected an under
and over voltage from the mains power. Switch
off and try rebooting. The DVR has a high level of
protection and is intelligently checking
conditions all the time.
Rotor Fault
<Flashing>
RP State
Error
<Flashing>
PFC
Corrector
<Flashing>