Step Seven: Drill hole in tank
Align the four feet of the pump with the four threaded holes in the pump
mounting plate.
Mark a point on the sprayer tank directly below the center of the bypass port of
the regulator.
Using a 9/16" drill bit (not included) drill a hole through the top of the tank in the
marked position.
Remove plastic debris from inside the tank (if chemicals have been used inside
the tank, refer to pg. 27 step 4 for personal decontamination after removing
debris).
Step Eight: Install rubber grommet (784519) into hole in
tank
Apply soap to rubber grommet.
Press grommet into the 9/16" hole in the sprayer
tank. Ensure the bottom lip of the grommet is fully
through the hole, and the top lip is flush with the
top of the tank.
Step Nine: Reinstall pump onto sprayer
Install QC x 3/8" HB fitting (791569) into bypass port of regulator. To insert
quick connect fittings, lubricate O-ring with water and twist fitting while inserting
into pump port. Secure with steel clip.
Apply soap to bypass fitting on regulator.
Press bypass fitting into the grommet.
Reinstall four screws through pump feet and into threaded holes in the pump
mounting plate.