![Nortel Observe Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/nortel/observe/observe_user-manual_1707238114.webp)
Nortel Proprietary
9.7 Troubleshooting RSM Parsing
If the RSM stream is not being received correctly, the introduction BUI page will
appear as shown in the figure below, with the card appearing in a red colour and
the error message relating to RSM failure appearing.
Figure 47 RSM Error Message on introduction page
If this occurs, follow the following steps to resolve the issue.
1. Ensure that the network interface connection between the SCCS server and the
Nortel Remote Agent Observe card is up. This can be achieved by pinging the
SCCS server C-LAN IP address from the card terminal.
->ping “aa.bb.cc.dd”,2
where aa.bb.cc.dd is the C-LAN IP address of the SCCS server.
If this returns successfully, move to step 2.
Otherwise, examine the Nortel Remote Agent Observe cabling
(->linkGetOperation 0), Nortel Remote Agent Observe IP address (-> ifShow),
and the network configuration between the card and the SCCS server.
Planning, Installation and Administration Guide
114
The red colour of
the card and the
RSM error
message indicate a
problem is
occurring.