background image

10

  

MM271 Installation Instructions

MM271 Installation Instructions

  

11

2

POWER

OFF

120

AUTO CLOSE 

TIME 

MIN

MAX

STALL

FORCE

ON  OFF

SG1

ED1

K1

06

AVR-ISP

D1

C2

C7

C15

LED3

D15

R20

IC4

D16

D13

D14

K2

BATT-       BATT+

STATUS

ANT SHLD

S9.8874

EDGE

COM

LOCK+

LOCK -

PGOK200    Rev.    XC

M_BLK
M_RED

VAR2

GRN

VAR3

VAR3

VAR1

VAR4

VAR5

PF1

VAR6

WHT

GTO Inc.   Tallahassee, FL

CYCLE

EXIT

SAFETY

COM

CHGR

CHGR

MIN

MAX

STALL

FORCE

POWER

OFF

120

AUTO CLOSE 

TIME 

MIN

MAX

STALL

FORCE

ON  OFF

SG1

ED1

K1

06

AVR-ISP

D1

C2

C7

C15

LED3

D15

R20

IC4

D16

D13

D14

K2

BATT-       BATT+

STATUS

ANT SHLD

S9.8874

EDGE

COM

LOCK+

LOCK -

PGOK200    Rev.    XC

M_BLK
M_RED

VAR2

GRN

VAR3

VAR3

VAR1

VAR4

VAR5

PF1

VAR6

WHT

GTO Inc.   Tallahassee, FL

CYCLE

EXIT

SAFETY

COM

CHGR

CHGR

MIN

MAX

AUTO CLOSE

TIME

3

4

POWER

ON  OFF

SG1

ED1

K1

06

A

VR-ISP

D1

C2

C7

C15

LED3

D15

R20

IC4

D16

D13

D14

K2

BATT

-       BA

TT+

STATUS

ANT SHLD

S9.8874

EDGE

COM

LOCK

+

LOCK

 -

PGOK200  

  Rev

.    XC

M_BL

K

M_RED

VAR2

GRN

VAR3

VAR3

VAR1

VAR4

VAR5

PF1

VAR6

WHT

GTO Inc

.   Ta

llah

ass

ee, 

FL

CYCLE

EXIT

SAFETY

COM

CHGR

CHGR

OFF

120

AUTO CL

OSE 

TIME 

MIN

MAX

STALL

FORCE

1

POWER

ON  OFF

SG1

ED1

K1

06

A

VR-ISP

D1

C2

C7

C15

LED3

D15

R20

IC4

D16

D13

D14

K2

BATT

-       BA

TT+

STATUS

ANT SHLD

S9.8874

EDGE

COM

LOCK+

LOCK -

PGOK200  

  Rev

.    XC

M_BL

K

M_RED

VAR2

GRN

VAR3

VAR3

VAR1

VAR4

VAR5

PF1

VAR6

WHT

GTO Inc

.   Ta

llah

ass

ee, 

FL

CYCLE

EXIT

SAFETY

COM

CHGR

CHGR

OFF

120

AUTO CLOSE 

TIME 

MIN

MAX

STALL

FORCE

Do not use the Dual Sense Stall Force adjustment to compensate for a 
gate that is sticking or binding. 

 Excessive Stall Force may cause damage to the gate operator, 

gate system, Bodily Injury or Death.
The Stall Force adjustment controls the amount of force the operator 
will apply against an obstruction before it stops and reverses direction. 
The adjustment on the control board operates like a volume control 
on a radio. It controls the amount of force the operator will apply to an 
obstruction before it automatically reverses direction.
The Stall Force adjustment is located on the control board. Turn the 
“STALL FORCE” arrow in the center of the potentiometer with small 
flat head screwdriver. Adjust the sensitivity to the point where the gate 
operates without obstructing from its own weight or the wind conditions 
in your area.
You may need to increase the stall force in cold weather due to 
increased resistance from gate hinges. However, the adjustment 
must remain as near to minimum as possible and when the weather 
improves decrease the setting to the appropriate position.

NOTE: 

The stall force setting must at the lowest (minimum) possible 

position. 

Close control box, unless you are adding additional accessories 
If adding additional accessories, see next page.

Turn the “AUTO CLOSE TIME” arrow in the center of the 
potentiometer with small flat head screwdriver to determine how 
long the gate will remain open before it automatically closes. The 
limits are OFF and 3 - 120 seconds. The factory setting is OFF.

SETTING DUAL SENSE DETECTION & AUTO CLOSE TIMER

For safety reason the Dual Sense Stall Force setting on the Mighty Mule control 
board comes from the factory set at set at the 10 o’clock position. This setting 
may need adjustment depending on the size and weight of the gate.

ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR 
SERVICING YOUR GATE SYSTEM.

CAUTION

CONNECTING ADDITIONAL DEVICES

Wiring Accessories through Control Board Wiring Knockout

Carefully remove wiring 
knockout (on cover) to insert 
accessory wires.

Remove control box cover.

Reattach control box cover.

Insert accessory wires 
through the knockout and 
route to the accessory input 
terminals on the control 
board. 
(See pg. 12)

ON/OFF Switch

Accessory Wires

(Photo beams, keypad, etc.)

Mighty Mule strongly recommends the use of additional obstruction detection devices. However, we do not 

endorse any specific brand names. Only use products that are listed to be in compliance with any applicable UL 

safety standards and national and regional codes.

PLEASE NOTE: Contact sensors, non-contact sensors, shadow loops, etc. are not included with the Mighty 

Mule. Refer to the sensor manufacturer’s instructions for information about installing accessory devices. 

The Mighty Mule ONLY accepts accessory devices with normally open dry contact outputs.

Make sure the operator power switch is turned OFF before connecting ANY 

device wiring to the terminals of the controller. Unplugging the transformer 

does not turn power to the operator off.

WARNING

With the Control Panel OFF, remove control panel cover by unscrewing 

center cover fastener.

Содержание Mighty Mule MM271

Страница 1: ...box from transformer wire not included Power Cable Closed Position Stop Plate PVC conduit not included to protect wire from lawn mowers and weed eaters Gate Bracket Warning Sign Single Gate Operator 1...

Страница 2: ...if you fail to do so Nortek Security and Control LLC shall in no event be liable for direct indirect incidental special or consequential damages or loss of profits whether based in contract tort or a...

Страница 3: ...lad to give you the name and phone number of a Linear dealer near you BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR Read these instructions carefully to become familiar with all parts and i...

Страница 4: ...t from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gate to activate the gate operator 5 Do not activate your gate o...

Страница 5: ...at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators...

Страница 6: ...ded not included 7 foot minimum Important Safety Information Important Safety Information Warning signs alert people of automatic gate operation and are required when installing Mighty Mule Automatic...

Страница 7: ...TE ACTIVITY CHART Single Gate Winter Ratings Zone 1 Zone 2 Zone 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charg...

Страница 8: ...rator near the center line of the gate to keep the gate from twisting and flexing and to avoid back splash from rain Copper clad ground rod not included Ground Ground 2 Inches or Less above ground Cop...

Страница 9: ...me types of installations require u bolts Additional washers or a metal plate may be needed for wooden post Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts lon...

Страница 10: ...post and gate cross support Attach post bracket assembly to gate post NOTE Must be through bolted GATE OPERATOR INSTALLATION 1 2 3 5 6 12 T L L V P 2 1 1 13 2 14 15 4 H 1 5 1 2 2 1 Attach and secure o...

Страница 11: ...CHGR OFF 120 AUTO CLOSE TIM E MIN MAX STA LL FORCE 6 Locate power outlet and identify wire path to control box NOTE If OUTLET is OUTSIDE use weatherproof cover Inspect the wire to insure the preventi...

Страница 12: ...HGR terminal Solar Panels connect in PARALLEL Position solar panel facing sun and in a non shaded open area that allows 8 hours of direct sunlight for a full charge SOLAR PANEL INSTALLATION For multip...

Страница 13: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen...

Страница 14: ...tructing from its own weight or the wind conditions in your area You may need to increase the stall force in cold weather due to increased resistance from gate hinges However the adjustment must remai...

Страница 15: ...ntact edge sensor Activation of this input while gate is moving will cause it to reverse direction for 2 seconds Activation of this input while idle will prevent gate from running 8 COM Common Negativ...

Страница 16: ...Gate h h Gate for Level and Plumb h h Stall Force Adjustment h h Disconnect Obstruction Detection Devices h h Battery connections h h Check fuse 1 beep every 20 seconds off Low Battery Condition h h T...

Страница 17: ...Time Fax 850 575 8950 Web site www mightymule com Telephone 800 543 1236 For 24 hour 7 days a week trouble shooting and sup port online go to our TECH WIZARD site at www mightymule com Repair Service...

Страница 18: ...s for maximum stability and security Comes with a keyed manual release Accessories Replacement Transformer RB571 Standard 18 volt 2260 mA AC transformer for maintaining the battery with the Mighty Mul...

Страница 19: ...ffic must use the pedestrian gate 5 Warning signs have been installed on each side of the gate in highly visible locations These signs must remain at all times 6 There are no controls installed on the...

Отзывы: