background image

Radio Receiver 

Built on Board

315 MHz

Installation Date

CONTACT INFORMATION

MEDIUM DUTY LOGIC 

USER'S GUIDE

MH5011URCHB

MH5011ULCHB

MT5011UCHB

MJ5011UCHB

www.Raynor.com

Summary of Contents for MH5011ULCHB

Page 1: ...Radio Receiver Built on Board 315 MHz Installation Date CONTACT INFORMATION MEDIUM DUTY LOGIC USER S GUIDE MH5011URCHB MH5011ULCHB MT5011UCHB MJ5011UCHB www Raynor com...

Page 2: ...is released before reaching the close limit BASIC PROGRAMMING RECOMMENDED INSTALLATION B2 WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE Momentary contact to open close and stop Open overrid...

Page 3: ...Logic Board Electrical Box D14 LED LEARN 1 2 3 4 5 6 7 STOP CLOSE OPEN ALTERNATE INSTALLATION C2 WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE FACTORY DEFAULT Momentary contact to open an...

Page 4: ...D OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN R27 AUX ANT AUX ANT AUX ANT D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN TO ERASE ALL REMOTE...

Page 5: ...3 4 5 6 7 STOP CLOSE OPEN R27 Every press and release of the STOP button will add 5 seconds to the Timer to Close Example 30 second TTC 6 presses of the STOP button D14 COM INTRLK STOP LED OPEN CLOSE...

Page 6: ...Press CLOSE button The door should move in the close direction Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode Press STOP button The door should stop...

Page 7: ...f the emergency release handle Emergency disconnect will close TO DISCONNECT DOOR FROM OPERATOR TO RECONNECT DOOR ARM TO TROLLEY 1 1 2 3 Emergency Disconnect Door Arm To prevent possible SERIOUS INJUR...

Page 8: ...hoist operation Refer to Model MJ instructions for emergency operation When the manual chain hoist sash chain is engaged electrical operation will not function 1 2 Keyhole Bracket EMERGENCY DISCONNEC...

Page 9: ...dealer DOOR REVERSES UNEXPECTEDLY Entrapment protection device activated Verify photoelectric sensors are aligned If photoelectric sensors are aligned and operator still does not operate properly con...

Page 10: ...10 OPERATOR NOTES...

Page 11: ...Button SECURITY Remote Control Includes visor clip Wireless Single Push Button Control SECURITY Rugged composite housing Wireless controls cannot be used in place of hard wired controls 1 2 4 5 7 8 0...

Page 12: ...d at the Open limit Input functions as Open input at all other times Also used with external radio controls 71 MLMOTION Door In Motion Provides dry contact and a terminal block with contacts switched...

Reviews: