background image

Raynor Garage Doors
1101 E. River Road
Dixon, Illinois 61021
www.raynor.com

GARAGE DOOR OPENER

Models 3220RGD 1/2 HP

For Residential Use Only 

Owner’s Manual

Please read this manual and the enclosed safety materials carefully!

Fasten the manual near the garage door after installation.

The door WILL NOT CLOSE unless the Protector System

®

is connected and

properly aligned.

Periodic checks of the opener are required to ensure safe operation.

The model number label is located on the front panel of your opener.

TM

Summary of Contents for 2280RGD 1/2 HP

Page 1: ...l Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and pro...

Page 2: ...problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PIN 32 Repair Pa...

Page 3: ...your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift t...

Page 4: ...type and height of your garage door Survey your garage area to see if any of the conditions below apply to your installation Additional materials may be required You may find it helpful to refer back...

Page 5: ...is packaged in two cartons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material Part...

Page 6: ...ocket Align the two bolt holes in the rail with those in the motor unit bracket Insert two 1 4 20x5 8 hex bolts and lock nuts Tighten securely with a 7 16 socket wrench ASSEMBLY STEP 2 Install the Tro...

Page 7: ...ted to garage door BEFORE installing opener to avoid entanglement 5 Install garage door opener 7 feet 2 13 m or more above floor 6 Mount emergency release handle 6 feet 1 83 m above floor 7 NEVER conn...

Page 8: ...the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 12 for ceiling installation To prevent possible SERIOUS INJURY...

Page 9: ...P CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEILING MOUNT ONLY Door Spring Header...

Page 10: ...way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes an...

Page 11: ...r Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional g...

Page 12: ...track It should lie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installat...

Page 13: ...garage door you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires Use one rail channel for the door control wire and the other chan...

Page 14: ...s convenient for setting an ideal door to rail distance Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 l...

Page 15: ...ilize the two center mounting tabs you must triangulate the vertical brackets for additional stability Figure 3 6 Check to make sure the rail is centered over the door or in line with the header brack...

Page 16: ...top of motor unit above the terminal block on the back panel Figure 4 5 Strip 7 16 11 mm of insulation from each set of wires Insert door control wire into quick connect terminals by color white wire...

Page 17: ...the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Secure with an...

Page 18: ...k Wire PERMANENT WIRING CONNECTION White Wire Black Wire WARNING CAUTION WARNING WARNING INSTALLATION STEP 11 Complete Safety Reversing Sensor Installation ALIGNING THE SAFETY SENSORS Plug in the open...

Page 19: ...cket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insul...

Page 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Page 22: ...ener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manually close the door...

Page 23: ...ined in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close co...

Page 24: ...the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum am...

Page 25: ...e 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment of d...

Page 26: ...t when the Light feature on the Multi Function Door Control is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage...

Page 27: ...to stop the door while it s opening Light feature Press the Light button to turn the opener light on or off It will not control the opener lights when the door is in motion If you turn it on and then...

Page 28: ...or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operati...

Page 29: ...Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door tr...

Page 30: ...control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminal...

Page 31: ...d release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate...

Page 32: ...the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The motor unit lig...

Page 33: ...sending eyes with 3 9 m 2 conductor bell wire attached 10 41A5266 1 Safety sensor bracket 11 41B4494 1 2 Conductor bell wire white white red 12 178B35 Curved door arm section NOT SHOWN 41A4675 7 Insta...

Page 34: ...ket light socket limit switch 8 41A5388 Motor drive assy complete with 8a 144B41 22T Pulley 8b 144B42 28T Pulley 8c 20B17 Drive belt 8d 158A69 Retainer rings 8e 41C556 Isolator bracket spacers 8f 41A5...

Page 35: ...This temporary password can be limited to a programmable number of hours or entries 59LM Outside Keylock Operates the garage door automatically from the outside when remote control is not handy 371RGD...

Page 36: ...ipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be re...