4
MM271 Installation Instructions
MM271 Installation Instructions
5
C
1
1
1
2
2
POWER
ON OFF
SG1
ED1
K1
06
A
VR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT
-
BATT+
STATUS
ANT
SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200
Rev
. XC
M_BL
K
M_RED
VAR
2
GRN
VAR3
VAR
3
VAR1
VAR
4
VAR
5
PF1
VAR
6
WHT
GTO Inc.
Tall
aha
ssee
, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUT
O CLOSE
TIME
MIN
MAX
STAL
L
FORCE
3
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
4”
S9.8874
4
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
Correct
Wrong
Wrong
Wire
Screwed into
wire insulation
Exposed strands
of wire
OFF
POSITION
5
POWER
ON OFF
SG1
ED1
K1
06
A
VR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT
- BA
TT+
STATUS
ANT
SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200
Rev
. XC
M_BLK
M_RED
VAR
2
GRN
VAR3
VAR
3
VAR1
VAR
4
VAR
5
PF1
VAR
6
WHT
GTO Inc.
Tall
aha
ssee
, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUT
O CLOSE
TIME
MIN
MAX
STALL
FORCE
6
••
••
•••
••
••
••
••
Locate power outlet and identify wire path to control box.
NOTE:
If OUTLET is OUTSIDE use weatherproof cover. Inspect
the wire to insure the prevention of damage.
CONTROL BOX & BATTERY INSTALLATION
Mount control box on piece of treated plywood then attach it to
post or fence using screws.
Locate control box mounting area.
IMPORTANT:
Be sure to mount
box at least 3 feet from AC power and 3 feet off the ground.
Make sure control box is turned OFF. Place 12 Volt battery and
weatherproof battery box within 6 feet of the control box Attach the
battery harness wires from the control box to the battery terminals.
Tighten the bolts, washers, and nuts and place the cover on the
weatherproof box.
IMPORTANT:
Do not connect the transformer
or solar panel directly to the battery.
Use PVC conduit from ground up to control box.
Plug in transformer to power outlet. (Use of a surge protector is
highly recommended. If outdoors use weatherproof box.)
TRANSFORMER WIRING INSTALLATION
Strip 1/2” off 2 wires and twist ends. Attach wires to
transformer screw terminals.
With the Control Panel OFF, remove control panel cover by
unscrewing center cover fastener.
Feed 4” of low voltage wire through strain relief into box with
battery wire harness.
Insert black (–) wire into the top CHGR terminal.
Insert the red (+) wire into the 2ND CHGR terminal.
Attach cover back onto the control box.
WARNING
Before digging contact local authorities to locate underground utilities such as electric and gas service.
NOTE: If using a solar panel charging kit, go to
.