Copyright
©
2017 Nortek Security & Control LLC
27
1
Se ng the AWAY setpoints via the CONFIG command class does not maintain the delta-T
separa on.
3
Con
fi
g Parameters can be selec vely Enabled to be Sent Unsolicited by se ng the
appropriate bits in the AutoSend Con
fi
g Register #23
4
Any change to a Mechanical System se ng may cause the current HVAC opera on to
abort and start an MOT
5
An MOT/MRT change will not take e
ff
ect un l the next MOT or MRT cycle
6
The ba ery alert enable only applies to the periodic ba ery report (con
fi
g reg 185) and
not the built-in ba ery threshold alerts (con
fi
g regs 183, 184)
7
Schedule Enable (#38) must be enabled prior to se ng this parameter
Specifications
Power
C-Wire Input: 20-30VAC
Ba ery Power: 4 AA Ba eries
Operating Temperature
32° to 120°F (0° to 49°C)
Storage Temperature
-40° to 140°F (-40° to 60°C)
Messaging Capability
7 character alpha numeric display, with message scroll
Set-point Accuracy
1° F (0.5°C), Calibrates to +/- 7°F
Ambient Temperature Display
Accuracy
1° F (0.5°C)
Remote Control
Via Z-Wave
Standard Gas/Electric HVAC
Systems
2-stage hea ng, 2-stage cooling
Heat Pump HVAC System
3-stage hea ng, 2-stage cooling
Thermostat Connections
Uses standard thermostat connec ons (C,RC,RH,W1,W2/O,Y1,Y2,G) -
18 AWG
Regulator
United States: FCC Compliant to CFR47, Part 15B Canada: Industry
Canada RSS 210, Issue 8
Dimensions
5.75” (146mm) W, 4.5”(114.3mm) H, 1.00 (25.4mm) D
Screen Size
2.7” X 1.4” LCD w/white backlight (68.6mm X 35.6mm)
Buttons
4 mechanical bu ons (Mode, Fan, Up Arrow, Down Arrow)
Certification
FCC Part 15, Industry Canada
Regulatory Information
FCC ID: WIBTZW011
This device complies with Part 15 of the FCC Rules. Opera on is subject to the following two condi ons: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired opera on.
This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in
a residen al installa on. This equipment generates and can radiate radio frequency energy and, if not installed
and used in accordance with the instruc ons, may cause harmful interference to radio communica ons.
However, there is no guarantee that interference will not occur in a par cular installa on. If this equipment does
cause harmful interference to radio or television recep on, which can be determined by turning the equipment
o
ff
and on, the user is encouraged to try to correct the interference by one or more of the following measures.
Reorient or relocate the receiving antenna
Increase the separa on between the equipment and receiver
Connect the equipment into an outlet on a circuit di
ff
erent from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Any changes or modi
fi
ca ons not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Содержание Gocontrol GC-TBZ48L
Страница 31: ...Copyright 2017 Nortek Security Control LLC 29 ...
Страница 32: ...10006936 C ...