CONTENTS

SAFETY INFORMATION  . . . . . . . . . . . . . . . . 2

FOR YOUR SAFETY  . . . . . . . . . . . . . . . . . . . . . . . 2

SYSTEM OPERATION  . . . . . . . . . . . . . . . . . . 2

THERMOSTATS. . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTERMITTENT IGNITION DEVICE  . . . . . . . . . . . 2
INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
OPERATING INSTRUCTIONS. . . . . . . . . . . . . . . . 3
TO SHUT DOWN THE FURNACE . . . . . . . . . . . . . 3
TO LIGHT THE FURNACE. . . . . . . . . . . . . . . . . . . 3
VENT SAFETY SYSTEM . . . . . . . . . . . . . . . . . . . . 3
100% SHUT OFF . . . . . . . . . . . . . . . . . . . . . . . . . . 3

EXPLAIN UNIT FUNCTION  . . . . . . . . . . . . . . 4

GENERAL MAINTENANCE  . . . . . . . . . . . . . . 4

HEATING SYSTEM INSPECTION . . . . . . . . . . . . . 4
BURNER AND PILOT CHECK . . . . . . . . . . . . . . . . 4
CLEANING BURNERS . . . . . . . . . . . . . . . . . . . . . . 5
CLEANING FLUE PASSAGES AND 
HEATING ELEMENTS . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ECONOMIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
BLOWER ASSEMBLY  . . . . . . . . . . . . . . . . . . . . . . 6
BLOWER SHAFT BEARING  . . . . . . . . . . . . . . . . . 6
MOTORS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CONDENSER COIL . . . . . . . . . . . . . . . . . . . . . . . . 7
REGISTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . 7

BEFORE CALLING A SERVICE PERSON  . . . . . . 7

REPLACEMENT PARTS  . . . . . . . . . . . . . . . . 8

The manufacturer recommends that the “User” read all sections of this
manual and keep the manual for future reference. 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.

- Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not 
use any phone in your building.

Leave the building immediately.

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas sup-
plier’s instructions.

If you cannot reach your gas supplier, call 
the fire department.

- Installation and service must be per-

formed by a qualified installer, service
agency or the gas supplier.

®  

Содержание Thermostat

Страница 1: ...FORE CALLING A SERVICE PERSON 7 REPLACEMENT PARTS 8 The manufacturer recommends that the User read all sections of this manual and keep the manual for future reference FIRE OR EXPLOSION HAZARD Failure...

Страница 2: ...pply air duct Confirm the equipment is well supported and there are no signs of deterioration The manufacturer recommends that main burner ignition device and controls are inspected by a qualified ser...

Страница 3: ...his gas furnace is equipped with an automatic reset high temperature sensor or rollout switch which in the unlikely event of a sustained main burner flame rollout will shut off the flow of gas by clos...

Страница 4: ...s or other debris If any soot is found it is rec ommended a qualified service technician be called immediately If any blockage is found it must be cleared immediately Check for obvious signs of deteri...

Страница 5: ...s 7 Brush out the inside of the flue collector box and the flue baffles 8 Run the wire brush down the vent hoods from the flue collector end 9 If soot build up is particularly bad remove the vent moto...

Страница 6: ...RS Outdoor fan motors are permanently lubricated and require no maintenance Ventor motor is factory lubricated for an estimated 10 year life Indoor Blower Motor and Drive The indoor blower motor featu...

Страница 7: ...ly dirty a hose can be used to wash the coil from the inside out while brushing a soapy solution on the outside REGISTERS Supply and return air registers must be open when the unit is in operation Obs...

Страница 8: ...19036 000 DM180 035 19697 000 DH180 035 19413 000 DR180 SINGLE PACKAGE AIR CONDITIONER GAS ELECTRIC 20 TON REPLACEMENT PARTS FORM No RESPECTIVE MODEL No 035 18898 000 DJ240 1 035 19799 000 DJ240 2 03...