CONDENSER COIL

An annual check and cleaning, if necessary, of the out-
door coil should be done. Cleaning should be as often
as necessary to keep the coil clean. Clean any debris
and dirt from the outside coil face with a brush being
careful not to damage the fins. If extremely dirty, a hose
can be used to wash the coil from the inside out while
brushing a soapy solution on the outside.

REGISTERS

Supply and return air registers must be open when the
unit is in operation. Obstructions must not be allowed
to block airflow in or out of the registers.

TROUBLESHOOTING

BEFORE CALLING A SERVICE PERSON:

A. Check thermostat setting and insure thermostat is 

calling for heat or cooling.

B. Check thermostat for lint, etc.

C. Check fuses or circuit breakers.

D. Check filters for excessive dust accumulation.

 

Содержание Thermostat

Страница 1: ...FORE CALLING A SERVICE PERSON 7 REPLACEMENT PARTS 8 The manufacturer recommends that the User read all sections of this manual and keep the manual for future reference FIRE OR EXPLOSION HAZARD Failure...

Страница 2: ...pply air duct Confirm the equipment is well supported and there are no signs of deterioration The manufacturer recommends that main burner ignition device and controls are inspected by a qualified ser...

Страница 3: ...his gas furnace is equipped with an automatic reset high temperature sensor or rollout switch which in the unlikely event of a sustained main burner flame rollout will shut off the flow of gas by clos...

Страница 4: ...s or other debris If any soot is found it is rec ommended a qualified service technician be called immediately If any blockage is found it must be cleared immediately Check for obvious signs of deteri...

Страница 5: ...s 7 Brush out the inside of the flue collector box and the flue baffles 8 Run the wire brush down the vent hoods from the flue collector end 9 If soot build up is particularly bad remove the vent moto...

Страница 6: ...RS Outdoor fan motors are permanently lubricated and require no maintenance Ventor motor is factory lubricated for an estimated 10 year life Indoor Blower Motor and Drive The indoor blower motor featu...

Страница 7: ...ly dirty a hose can be used to wash the coil from the inside out while brushing a soapy solution on the outside REGISTERS Supply and return air registers must be open when the unit is in operation Obs...

Страница 8: ...19036 000 DM180 035 19697 000 DH180 035 19413 000 DR180 SINGLE PACKAGE AIR CONDITIONER GAS ELECTRIC 20 TON REPLACEMENT PARTS FORM No RESPECTIVE MODEL No 035 18898 000 DJ240 1 035 19799 000 DJ240 2 03...

Отзывы: