CONTROLLER & LOW SALT ELECTROLYSE UNIT TYPE NORSUPONE
CONTROLLER & LOW SALT ELECTROLYSE UNIT TYPE NORSUPONE
EN
C.7.9 CONTROLLING THE SALT CHLORINATOR
To control the ORP and pH of slide on the respective
options after turning the salt chlorinator ON. Boost option
has also given on the same screen. You cannot control
the ORP and Ph values if the salt chlorinator is OFF or it is
in BOOST mode. The pH and ORP value range that we
can control using app is 6.8 to 7.8 and 500-900.
Fig. 63: Shows the Controlling of ORP & PH
Fig. 64: Shows the Boost mode
To add sensors
The customer can add sensors under a controller.
Temperature sensor, PH electrode, ORP sensor and
EC electrode are the available sensors. To add
sensors, follow the given steps:
• Choose Smart Pool from the navigation drawer,
new page will be opened
• Tap on the add icon, two options, Devices and
Sensors will be shown
• Choose Sensors option, list of devices will be
displayed, select the one that you would like to add
C.7.10 TO ADD TEMPERATURE SENSOR
• Tap on the add icon
• Choose Sensors option
• Select Temperature Sensor from the device list, the
selected device and port number will be shown
• Tap on the Connect option at the bottom of the
page, the sensor will be added
Fig. 61: Shows the
confirmation
pop-up
Fig. 62: Shows the
field to enter the
value and the
Submit option
Fig. 68: Shows the
added Tempera-
ture Sensor under
the Smartpool
controller
Fig. 66: Selecting
Temperature
Sensor from the
sensor list
Fig. 67: Shows the
Connect/Add option
Fig. 65: Shows the