Maintenance
5‐2
Part 7192568-03
E
2020 Nordson Corporation
Vibratory Table
Check functionality of the
motor and condition of AV
mounts
TT
2000
No excessive resonance
Visual inspection
Prodigy High-
Capacity HDLV
Transfer Pump
Replacement of wear parts
TT
2000
Replace fluidising tubes and all
pinch valves at the same time
Insertion tool (part
of the Pinch Valve
Kit)
Damper
Functional check of the
dampers
TT
2000
Check opening and closing func
tionality. Check for airflow restric
tions (cloth, paper, bag etc.)
Visual inspection
Vibratory Table
Check the function of the
weight cell
TT
2000
Use a predefined weight to con
firm the calibration
Visual inspection,
Physical inspec
tion, Predefined
weight
Hopper
Level
Sensor
Functional check of level
sensors
TT
2000
Check if level sensors are detect
ing correctly by covering and un
covering the level sensors. Adjust
the settings if needed.
Visual inspection,
Physical inspec
tion
Hopper
Check the hopper banger is
functioning
TT
2000
Check that powder releases so no
powder accumulates on the
hopper walls and level sensors
Visual inspection
Hopper
Check tightness of the
hopper lid
TT
2000
No powder leakage is allowed. In
case of powder leakage, adjust
the lid hinges and check the con
dition of the hopper seals
Visual inspection
Sieve
Check the tension of the
sieve screen
TT
2000
Check the tension value is be
tween 20-25 N/cm
Tension meter
Hopper
Functional check of the
pinch valve (empty)
TT
2000
Fully opening and fully closing
(operation: 2 bar). If not opening/
closing properly then replace
Visual inspection
Hopper
Replace the pinch valve
(empty)
TT
4000
Pinch valve kit,
Pinch valve
wrench (PN
1610714)
SHD II Feed
Centre
Measure the airflow at the
face of the SHD Feed
Centre
TT
4000
Airflow min 0.25 m/s. Exhaust air
flow during colour change = 3000
m3/hr. During colour change =
1500 m3/hr
Air measurement
protocol, Air flow
meter (e.g. Testo
405i)
Grounding
Points
Measure point to point
grounding of whole system
TT
4000
<1 ohm, point to point
Multimeter
(e.g.BEHA ProIn
stall 100,
SN4225110)
Booth grounding
protocol
Sieve Maintenance
Refer to the manufacturer's sieve manual for more information on sieve
maintenance. This can be obtained from your local Nordson representative.
Encore HD Pump Maintenance
For maintenance on the Encore HD Pump, refer to the technical manual
1605708-03. For the complete Encore HD Automatic System Pump Panel
refer to technical manual 1612312-01.