Installation
3‐2
Part 7192568-03
E
2020 Nordson Corporation
Electrical Connections
Caution:
Equipment damage may occur if the electrical panel is connected
to any line voltage other than that stated on the identification plate.
WARNING:
Power to the Spectrum HD Generation II (SHD II) feed center
must be supplied from a locking disconnect switch or breaker. Failure to
observe this warning may result in a severe shock during installation or
repair.
Make sure that all electrical cables are correctly rated and suitable for the
ambient temperature of the installation area. Provide adequate fuse/circuit
protection from the power supply. Refer to the foldout wiring diagrams and
schematics at the end of this manual for more information.
Before starting up the SHD II feed center, turn on the feed center power and
refer to the Setup procedure to program the controls for the application. This
should be performed only by a Nordson field engineer or technician.
Pneumatic Connections
For the connection size, location and volume required please refer to your
Service Requirements drawing or contact your Nordson representative.
Clean, dry, compressed air should be supplied from a refrigerated or
desiccant air dryer and filter/separators. Refer to Specifications in Section 2
for compressed air specifications.
NOTE:
For information on the Pump Panel please refer to technical manual
on Nordson emanuals website.