Troubleshooting
4-10
Part 1618871
−
01
2020 Nordson Corporation
Flow Node
See Figure 4-5 and refer to Table 4-4. Use the Flow Node LEDs to help
diagnose problems.
LED
Function
LED
Color
LED State
Fault Correction
LED1
+24 V Power
Green
Normal: ON
Fault: OFF
If LED1 is OFF on all flow nodes, check PS1 for
+24 Vdc (refer to
Power Supplies
troubleshooting on page 4-8).
If LED1 OFF only on singlet flow node, check for
shorted valve wiring.
LED2
+5 V Power
Green
Normal: ON
Fault: OFF
If LED2 is OFF and LED1 is ON, either defective
LED or replace flow module.
DS1
Communication
Green
Normal: ON
Fault: OFF
Check CAN network terminations are correct
(Measure 60
Ω
).
Check for PLC fault.
Check flow node cabling.
Check manual gun connections P4.
DS2
Fault
Red
Normal: OFF
Fault: ON
Check Alerts screen through Engage controller
touchscreen for fault codes.
High flow fault.
Low flow fault.
Содержание Encore
Страница 4: ...Change Record ii Part 1618871 01 2020 Nordson Corporation ...
Страница 8: ...Table of Contents vi Part 1618871 01 2020 Nordson Corporation ...
Страница 44: ...Installation 3 20 Part 1618871 01 2020 Nordson Corporation ...
Страница 64: ...Troubleshooting 4 20 Part 1618871 01 2020 Nordson Corporation ...
Страница 77: ...Parts 6 3 Part 1618871 01 2020 Nordson Corporation This page intentionally left blank ...