Installation
3-18
Part 1618871
−
01
2020 Nordson Corporation
Spray Gun Cable Connections
See Figure 3-10. Connect the automatic spray gun cables to the
receptacles on the rear panel of the Engage console. Connect spray gun 1
cable to receptacle 1, spray gun 2 cable to receptacle 2, and so on.
Odd Number of Spray Guns
Engage systems are sold configured for an even number of spray guns.
Each spray gun controller card in the console controls two spray guns. If
the system is configured for an odd number of spray guns, the fault LED on
the card with only one spray gun connected will light.
NOTE:
The unused spray gun must be the highest even-number spray
gun. For example, if there is an 8-spray gun system, then number 8 must
be the unused spray gun. The spray gun card receptacles are labeled on
the circuit boards as A (odd-number spray gun) and B (even-number spray
gun).
Included in the bag with the console keys is a bulkhead seal and jumper.
The jumper disables the spray gun not detected fault LED on the spray gun
card.
Cap the unused cable receptacle with the bulkhead seal, then open the
console door and unplug the receptacle harness from the spray gun card.
Install the jumper in the card receptacle.
Refer to the Parts section for seal and jumper part numbers.
Bulkhead
Seal
Jumper
Install in #8 Card Receptacle
Spray Gun Card
Harnesses
Receptacle #8
1
2
3
4
5
6
7
8
Seal and Jumper Installation
−
Example Showing 8-Spray Gun System Using Seven Spray Guns
Содержание Encore
Страница 4: ...Change Record ii Part 1618871 01 2020 Nordson Corporation ...
Страница 8: ...Table of Contents vi Part 1618871 01 2020 Nordson Corporation ...
Страница 44: ...Installation 3 20 Part 1618871 01 2020 Nordson Corporation ...
Страница 64: ...Troubleshooting 4 20 Part 1618871 01 2020 Nordson Corporation ...
Страница 77: ...Parts 6 3 Part 1618871 01 2020 Nordson Corporation This page intentionally left blank ...
Страница 94: ...Parts 6 20 Part 1618871 01 2020 Nordson Corporation ...