4103936
1
2
Installation
A 1-54
E
2000 Nordson Corporation
All rights reserved
41-3000
V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
To Set Standby and Heater Times
The clock feature turns the heaters on or off, or takes the unit into and
out of the standby mode at preset times. Using a seven-day, 24-hour
format, the clock can store two sets of times, referred to as intervals, for
each day of the week. Each interval can store four time settings:
S
one to enter standby
S
one to exit standby
S
one to turn the heaters on
S
one to turn the heaters off
Follow this procedure to set times for entering and exiting standby and for
turning heaters on and off. After you have programmed the clock, use
the CLOCK key to turn the clock feature on and off. The CLOCK light
turns on when the clock feature is active.
NOTE:
If you have enabled the password feature, you must change the
number in the Multipurpose display (500) to the password (321) and
press the Enter key before the system will allow you to change the
clock settings.
1. See Figure A 1-36. In the System Setup area, press the Move Up
and Move Down keys (1) until the light next to the feature you wish to
set turns on.
NOTE:
When you select any of the standby or heater on/off settings,
the unit selects an interval. The INTERVAL 1 light (2) turns on as a
default.
Fig. A 1-36 Selecting Standby and
Heater Times
1. Move Up and Move Down keys
2. INTERVAL lights