Installation
A 1-29
E
2000 Nordson Corporation
All rights reserved
41-3000
V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
CAUTION:
Operate the unit only when it is connected to the
correct line voltage, as shown in Table A 1-7. Operating the unit
at a different voltage can damage the unit or impair its
performance.
4. Ensure that your unit has the correct voltage specification to accept
the type of electrical service that you will be connecting to it.
Table A 1-7 shows all the Series 3000
V
voltage specifications and the
types of electrical service that you can connect to each.
Table A 1-7 Types of Electrical Service for Each Voltage Specification
Unit Voltage
Specification
Voltage
Code (see
Note B)
Types of Service You Can Connect to the Unit
See Note
200--240 VAC
or
3 AC 230V
or
3/PE AC 200--240V
1
200--240 VAC 1 (two wire service without a neutral)
200--240 VAC 3 (three wire service without a neutral)
3/N/PE AC 400/230V
2
230 VAC 1 (two wire service, including a neutral)
400/230 VAC 3 (four wire service, including a neutral)
C
D
3 AC 400V
3
400 VAC 3 (three wire service without a neutral)
NOTE A: The voltage specification is shown in the VOLTS (ac) portion of the unit’s identification plate.
B: The voltage code is part of your unit configuration code. It is included here for information only and is
not something you need to know to install your electrical service line. For more information about your
unit configuration code, refer to
Explanation of Configuration Code
at the end of the
Description
section.
C: This type of service also includes voltage used primarily in the British Commonwealth: 240 VAC 1
(two wire service, including a neutral).
D: This type of service also includes voltage used primarily in the British Commonwealth:
415/240 VAC 3 (four wire service, including a neutral).