Installation
A 1-76
E
2000 Nordson Corporation
All rights reserved
41-3000
V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
Table A 1-25 Record of Customized SYSTEM SETTINGS Features
Feature
Default
Options Available
(Programming Code)
Revised Setting
Password Enable
Off (0)
Off (0) or On (1)
System-Ready Time
Delay
18 minutes
From 0 to 60 minutes
Overtemperature Setpoint
218
C (425
F)
From 52 to 246
C
(From 125 to 475
F)
Celsius/Fahrenheit
Fahrenheit
Celsius or Fahrenheit
Global Temperature Band
17
_
C (30
F)
From 6 to 28
C
(From 10 to 50
F)
Individual Temperature
Bands
17
_
C (30
F)
From 6 to 28
C
(From 10 to 50
F)
Sequential or
Simultaneous Startup
Sequential (1)
Sequential (1) or
Simultaneous (0)
Display Heater
Proportioning
No display (0)
No display (0) or
Show display (1)
Warning or Power
Notification
Warning (0)
Warning (0) or
Power (1)
Ready or Pump
Notification
Ready (1)
Pump (0) or
Ready (1)
Auto-Energize Pump
(piston pump units only)
On (1)
On (1) or Off (0)
Auto-Energize Heaters
On (1)
On (1) or Off (0)
Auto-Energize Pump
Temperature Setting
(piston pump units only)
READY condition (0)
READY (0) or
From 1 to 232
C
(From 1 to 450
F)
Auto-Standby Timeout
0 minutes
From 0 to 1440 minutes
In Standby Timeout
0 minutes
From 0 to 1440 minutes
Auto-Energize Pattern
Control
On (1)
On (1) or Off (0)
Record of Customized SYSTEM
SETTINGS Features