TROUBLESHOOTING
Super Claws Model LS-2
Section 6-6
MAR/2006 (4945-3500)
PROBLEM
POSSIBLE
CAUSE
SOLUTION
Light switch defective.
Connection at switch loose.
Connection at circuit breaker panel
loose.
Bulb or socket in light defective.
Repair or replace switch.
Tighten connection.
Tighten connection.
Replace bulb or socket.
Work Lights do not
work.
Wiring harness
Connection at light loose.
Light circuit breaker blown.
Light switch defective.
Bulb or socket in light defective.
Check harness, repair or
replace.
Tighten connection.
Reset circuit breaker. See next
page.
Repair or replace switch.
Replace bulb or socket.
Cooling Fan not
working
Loose connection at back of fan
Loose connection at circuit breaker
panel.
Loose connection on relay.
Tighten.
Tighten.
Tighten.
Brake Lights do not
work
Wiring harness.
Connection at light loose.
Light Circuit breaker blown.
Bulb or socket in light defective.
Switch on main logic board in wrong
position.
Check harness, repair or
replace.
Tighten connection.
Reset circuit breaker. See page
98
Replace bulb or socket.
See Appendix C, Periodic
Adjustments for Main Board
Settings.
Содержание Super Claws LS-2
Страница 2: ......
Страница 16: ...GENERAL Super Claws Model LS 2 Section 2 4 MAR 2006 4945 3500 Page Intentionally Left Blank ...
Страница 19: ...Super Claws Model LS 2 PRE OPERATION STARTUP MAR 2006 4945 3500 Section 3 3 MAIN CONTROL PANEL ...
Страница 30: ...PRE OPERATION STARTUP Super Claws Model LS 2 Section 3 14 MAR 2006 4945 3500 OPERATOR CONTROLS HAND CONTROLS ...
Страница 44: ...OPERATION SHUTDOWN Super Claws Model LS 2 Section 4 6 MAR 2006 4945 3500 This page intentionally left blank ...
Страница 76: ......