INSPECTION
Inspect the electrical system for clues to the malfunction. Check to see if the unit can be
operated without further damage to the system. Always check these items before turning
on switches or running the machine:
1.
Look for bare wires that could cause grounds or shorts. Shorted wires can
damage the charging system.
2.
Look for loose or broken wires.
3.
Inspect all connections, especially battery connection points. Cleaning harness
connectors or ground connections can often correct what appears to be a
malfunction.
4.
Check the battery electrolyte level. Continued loss of electrolyte fluid indicates
overcharing or cracked battery case.
5.
Inspect for overheated parts after the unit has been stopped for a while. They will
often smell like burned insulation. Put your hand on the alternator. Heat in these
parts, when the machine has not been operated for some time, is a sure clue to
charging circuit problems.
Many electrical failures cannot be detected even if the machine is started. If your visual
inspection does not indicate the possible malfunction refer to the electrical system
troubleshooting guide that follows.
The Electrical Schematic for this machine can be found at the back of this
TROUBLESHOOTING section and behind the Electrical tab of the manual.
Disconnect the battery before servicing this machine. Failure to do so could
result in personal injury from accidental engine startup.
Never shut off battery disconnect switch with the engine running. This could
cause damage to the voltage regulator, alternator, and/or electrical system.
Содержание Super Claws LS-2
Страница 2: ......
Страница 16: ...GENERAL Super Claws Model LS 2 Section 2 4 MAR 2006 4945 3500 Page Intentionally Left Blank ...
Страница 19: ...Super Claws Model LS 2 PRE OPERATION STARTUP MAR 2006 4945 3500 Section 3 3 MAIN CONTROL PANEL ...
Страница 30: ...PRE OPERATION STARTUP Super Claws Model LS 2 Section 3 14 MAR 2006 4945 3500 OPERATOR CONTROLS HAND CONTROLS ...
Страница 44: ...OPERATION SHUTDOWN Super Claws Model LS 2 Section 4 6 MAR 2006 4945 3500 This page intentionally left blank ...
Страница 76: ......