internal restriction
Travel relief set too low
Inspect and repair.
Check and reset
Hydraulic Oil Foams
Water in oil
Using wrong oil
Low hydraulic level
Damaged hydraulic oil lines
Air leak in suction line to hydraulic pump
or pump shaft seal leaking
Inspect oil for water. Drain and
add correct oil as specified
under "RECOMMENDED
LUBRICANTS".
Drain and add correct oil as
specified under
"RECOMMENDED
LUBRICANTS".
Fill
Inspect, repair or replace.
Inspect, repair or replace.
Hydraulic Oil Filter
Restriction Indicator
Light stays on all the
time (optional
equipment)
Restricted hydraulic oil filter.
Hydraulic oil filter restriction switch
Replace filter.
Replace switch.