16
4.6
H
YDRAULIC
I
NSTALLATION
If your sprayer has a valve block
with serial number 21.12732 or lower
then you must refer to Section 6 to
complete the hydraulic plumbing.
WARNING!
The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.
When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.
IMPORTANT:
Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.
4.6.1
Valve Mounting
1.
On a clean surface remove all plastic
plugs from the NORAC hydraulic Valve
(
V01
) (
Figure 13
).
Figure 13 – NORAC Valve Block
2.
Install the orifices (
F08
) into the "B"
ports as shown in
Figure 14
.
3.
Install the 6MB-6MOR fittings (
F02
)
into the “B” ports and tighten to 18 ft-
lbs.
4.
Install the 6MB-6MOR fittings (
F02
) in
the pressure (P) and tank (T) ports and
tighten to 18 ft-lbs.
5.
Install the 6MBP plugs (
F01
) into the A
ports of the NORAC valve block and
tighten to 18 ft-lbs.
Figure 14 – Valve Block Assembly
6.
A valve mounting plate (
B10
) is
provided with 5/16” NC bolts, nuts and
washers. Mount the valve plate directly
under the spray nozzle valves.
Содержание UC4+ NITRO Miller 3200 Series
Страница 10: ...7 Figure 3 Hydraulic Plumbing Schematic ...
Страница 27: ...24 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL 5 4 ITEM C03 44656D VALVE CABLE VARIABLE RATE DT ...
Страница 28: ...25 5 5 ITEM C04 44651 VALVE EXTENSION CABLE 5 6 ITEM C06 44687 CABLE UC3 SENSOR AMPM TO AMPF ...
Страница 29: ...26 5 7 ITEM C10 44650 22 NITRO POWER CABLE ...
Страница 30: ...27 5 8 ITEM C11 44688 VALVE DISCONNECT EXTENSION 4FT CABLE ...