15
Figure 11 – Roll Sensor Mounting with Respect to Sprayer Orientation
4.5.1
Boom Roll Sensor Mounting
The boom roll sensor is the roll sensor
with the temperature probe attached to it
(
E03
). To mount the boom roll sensor,
refer to these guidelines.
a)
The boom roll sensor must be attached
to the center part of the boom.
b)
Use cable-ties to secure the bracket to
a square edge feature (square tube).
c)
The AMP (circular) connector must be
pointing to the right hand wing (when
looking from the rear).
d)
The ring terminal on the boom roll
sensor is a temperature probe and must
be attached to the side of the valve
block (
Section 4.5.3
).
4.5.2
Chassis Roll Sensor Mounting
The chassis roll sensor must be attached to
the chassis of the sprayer. To mount the
chassis roll sensor, refer to the following
guidelines.
a)
The chassis roll sensor does not have a
temperature probe (
E04
).
b)
Cable-tie the bracket to a square edge
(square tube).
c)
The AMP (circular) connector must exit
towards the right hand wing (when
looking from the rear).
4.5.3
Temperature probe
Fasten the temperature probe (
E03
) to
the UC4+ valve block using the included
3/8x1/2” bolt.
Figure 12 – UC4+ Valve Block with
Temperature Probe Installed
The roll sensors must
be mounted with the
Amp connectors
pointing to the right.
Содержание UC4+ NITRO Miller 3200 Series
Страница 10: ...7 Figure 3 Hydraulic Plumbing Schematic ...
Страница 27: ...24 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL 5 4 ITEM C03 44656D VALVE CABLE VARIABLE RATE DT ...
Страница 28: ...25 5 5 ITEM C04 44651 VALVE EXTENSION CABLE 5 6 ITEM C06 44687 CABLE UC3 SENSOR AMPM TO AMPF ...
Страница 29: ...26 5 7 ITEM C10 44650 22 NITRO POWER CABLE ...
Страница 30: ...27 5 8 ITEM C11 44688 VALVE DISCONNECT EXTENSION 4FT CABLE ...