Sensor cables should run through the
mounting bracket tube and then behind
the member the bracket is mounted
onto. Cable-tie the connector in place.
The cable must not be allowed to hang
below the boom (
Figure 6
).
Figure 6 - Sensor Cable Routing
Avoid mounting sensors in
locations where they may read
from parts of the boom.
General mounting rules for UC4+
ultrasonic wing sensors:
a)
In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b)
The bottom of the sensor must be at
least 9 inches in front of the spray
nozzles.
c)
The bottom of the sensor must be at
least 9 inches above the spray nozzles.
d)
Ensure that there are no obstructions
within a 12-inch diameter circle
projected directly below the center of
the sensor.
e)
The sensor should be approximately
vertical at normal operating heights.
Figure 7 - Sensor Mounting Guidelines
A
B
B
D
C
Ultrasonic
Acoustic Cone