WindRunner™ self-balancing electric vehicle user’s manual
81
experience an acute shake in the mainframe. Warn the driver to get off. If it is an irreversible trouble, the
WindRunner shall power off automatically if alarm goes off for 20s.
Preliminarily determine the causes of trouble or alarm according to the flicker of LED at the moment of
alarming for solving the troubles. The followings are the common alarm, trouble and corresponding LED
conditions.
intelligent safety alarm (note: LED close to LOGO is blue and flicker):
red, red, red, red, blue,
flicker
An intelligent safety alarm. it is self-recoverable after troubles are solved.
A hint of battery capacity seriously insufficient.
You should charge the battery as soon as possible. If the trouble still exists
after charged, it may be caused by battery trouble. Please contact the
factory for repair.
red, red, blue, red, blue,
flicker
An intelligent safety alarm. it is self-recoverable after troubles are solved.
A hint of internal temperature too high. Usually arises at air
temperature >30
℃
, continuous running or direct exposure under sunlight.
Cut off the machine and put in a cool place. Continue riding only after the
temperature of machine has reduced to a safe range.