52
Service Manual – SC401, SCRUBTEC 344
04 - Control System - Battery
Main Machine Controller (EB1) Connectors (continues)
J108 TRACKCLEAN POWER JST B2P-VH (2 ways, vertical)
PIN
Description
Controller
in/out
V ref.
I max.
Connected to
1
Supply 0V (permanent)
out
0V
<1A
TRK.BU
2
24V (permanent)
out
24V
<1A
TRK.RD
1
2
Figure 35:
J203 GSM/UART/LED: LEOCO 3675P10VTA0 (10 ways, vertical)
PIN
Description
Controller
in/out
V ref.
I max.
Connected to
1
-
-
-
-
-
2
-
-
-
-
-
3
-
-
-
-
-
4
-
-
-
-
-
5
Output Machine turned on
out
5V
<1A
TRK.BN
6
Output Brush turned on
out
0V
<1A
TRK.WH
7
Output Vacuum turned on
out
5V
<1A
TRK.GY
8
-
-
-
-
-
9
Output Drive turned on
out
5V
<1A
TRK.PK
10
Input iButton
in
0V
<1A
TRK.YE
1
2
3
4
5
6
7
8
9
1
3
5
7
9
10
2
4
6
8
10
Figure 36: