161
Service Manual – SC401, SCRUBTEC 344
40 - Recovery System
Maintenance and Adjustments
Recovery Tank Cleaning
1 Drive the machine to the appointed disposal area
2 Ensure that the machine is off and the ignition key has been removed (if equipped)
3 Drain the water in the tank through the hose
4 Raise the recovery tank cover
5 Wash the inside of the recovery tank and the cover with clean water
6
Clean the vacuum grid (B), release the fasteners (A), open the grid (B) and recover the float (C) then
clean it carefully and reinstall it
7 Remove the debris collection tank (D) and open its cover, then clean it carefully and reinstall it on the
vacuum hose
8 Check the condition of the tank cover gasket (E)
Note:
The gasket (E) allows the creation of a vacuum in the tank, which is necessary to suck up the
recovery water.
9
If necessary, replace the gasket (E) by removing it from its housing (F). When fitting the new gasket,
position the joint (G) in the lower area, as shown in the figure.
10 Check that the seating surface (H) of the gasket (E) is in good condition, clean and suitable to form a
seal with the gasket itself
11 Close the recovery tank cover
Figure 4:
C
B
A
A
F
E
H
D
G
H
E