164
Service Manual – SC401, SCRUBTEC 344
40 - Recovery System
Removal and Installation
Vacuum Motor Unit
Removal
1 Switch off the machine and disconnect the battery connector
2 If present, drain the recovery tank, then lift it
3 Disconnect the connector (A)
4 Unscrew the 5 screws (B) and the tie cable (C), then remove the Vacuum motor unit (D) from the
machine
Figure 6:
A
D
C
B