37
Service Manual – SC401, SCRUBTEC 344
04 - Control System - Battery
Troubleshooting
General System Fault Code
Display on
the control
panel
Meaning
Conditions
What to do
Reset
6 battery
LEDs flashing.
Brush motor
overload.
Brush motor current higher
than parameter “
Brush
continuous current limit
”
(default: 25 Amp) for a
period of time longer
than parameter “
Time
for continuous current
overload
” (default: 30 sec.).
Check if there is dust or
debris preventing the
brush rotation.
Turn off the machine
using the Main button
.
Brush motor peak current
higher then parameter
“
Brush peak current limit
”
(default: 40 Amp).
Total current
overload.
Brush + Vacuum motors
current higher then
parameter “
Current sum
cutoff
” (default: 50 Amp)
or “
Current limit during
softstart
” (default: 50 Amp)
for a period of time longer
than parameter “
Time
for continuous current
overload
” (default: 30 sec.).
Check if there is dust or
debris preventing the
brush rotation.
Check if brush or
vacuum motor are stuck
/ issue into the harness.
Vacuum
system button
LED
flashing (fast
flashing: 0.5
sec. ON - 0.5
sec. OFF).
Vacuum system
motor overload.
Vacuum system motor
current higher than
parameter “
Vacuum
continuous current limit
”
(default: 16 Amp) for a
period of time longer
than parameter “
Time
for continuous current
overload
” (default: 30 sec.).
Check if there is dust or
debris preventing the
vacuum system motor
fan rotation.
Turn off the machine
using the Main button
Vacuum system motor
peak current higher than
parameter “
Vacuum peak
current limit
” (default: 30
Amp).