Solution System
96
Service Manual – SC3000
Maintenance and Adjustments
Solution/clean water tank emptying
1. Drive the machine to the appointed disposal area.
2. Turn the ignition key to “0”.
3. Remove the adapter from its housing inside the battery compartment.
4. Install the adapter (A) on the squeegee vacuum hose (B), then fasten it to the drain valve (C).
5. Turn the ignition key to “I” and turn on the vacuum system with the vacuum system push button
.
6. Open the drain valve (C) to drain the tank.
7. The valve (C) is open when it is in the position (D) and it is closed when it is in the position (E).
8. Then, turn of the vacuum system and drain the recovery tank with the hose.
9. Close the drain valve (C), remove the adapter (A) and install the vacuum hose (B) on the squeegee.
A
B
C
E
D
C
P100366