Control System
30
Service Manual – SC3000
Display of Current Values of Significant Variables, Hour Counters and
Stored Alarms (continued)
Variable description
Value meaning
Software Release
Software version loaded on the electronic board
Supply Voltage
Battery voltage (V)
Ref. Voltage
Drive pedal input voltage (V)
Drive Motor Voltage
Drive system motor output voltage (V)
Drive Motor Current
Drive system motor current (A)
Brushes Current
Brush deck motor current (mV) (*)
Vacuum Current
Vacuum system motor current (A)
Heatsink Temp.
Temperature detected on the electronic board heatsink (°C)
Hour counter: total
TOTAL HOUR COUNTER (h.min)
Hour counter: drive system
DRIVE SYSTEM HOUR COUNTER (h.min)
Hour counter: brushes
BRUSH HOUR COUNTER (h.min)
Hour counter: vacuum
VACUUM SYSTEM HOUR COUNTER (h.min)
Logged Alarm-N
ALARM STORAGE (possible) (**)
(*) The value is the same as the voltage drop on the F1 fuse, which is proportional to the current but does not
have the same value in Amp.
(**) See BLACK-BOX paragraph
Содержание SC3000
Страница 4: ...Table of contents 4 Service Manual SC3000 ...