Engine System - LPG 178
Service Manual – CS7000
Cranks but does not start – No Spark
Possible causes:
• Spark Control Module not powered up.
– Ignition request relay
– Woodward L Series Actuator not energizing ignition request relay
– Spark control module ground
• Crank Position Sensor
• Spark Control Module
• Wiring
• Ignition Coils (not likely that all 3 coils would fail at once)
Cranks but does not start (has sufficient spark)
Possible causes:
• No fuel
– Empty Tank
– Fuel lock off solenoid stuck closed
– Fuel lock off solenoid not energized
◦
Ignition request fuse – blown
◦
High coolant temp shut down relay – “Closed at rest” contacts not making connection
◦
Engine oil pressure switch - not opening for pressure
◦ Engine – Insufficient oil pressure to open switch
– Pressure Regulator
• Mechanical engine
–
Insufficient compression
– Plugged Intake
– Plugged Exhaust
• Actuator
– Not opening throttle
Содержание CS7000 Fuel Cell EcoFlex
Страница 110: ...Electrical System 110 Service Manual CS7000 Electrical Panel Contactor Relay location Electrical Panel ...
Страница 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Страница 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Страница 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Страница 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Страница 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Страница 154: ...Service Manual CS7000 154 Electrical System 56509170 Rev L Sheet 8 of 9 Before SN 1000048160 Kubota LPG before LEV E4 ...
Страница 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Страница 172: ...Engine System LPG 172 Service Manual CS7000 Low LP Pressure Switch Fuel Tank Pressure relief valve Fuel Tank Area ...
Страница 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...