Engine System, Diesel 229
Service Manual – CS7000
Low Oil Pressure Shutdown
Here is how the low oil pressure shutdown works. The main machine controller sends 12 V out connector J3
pin number 9 to the APECS governor controller and the oil pressure switch. When there is oil pressure, the
switch connects the voltage back as an “engine run signal” to the main machine controller connector J7 pin
number 4. Once the main machine controller has seen that the engine is running, it continues to monitor
that voltage. If engine oil pressure is lost, the “engine run signal” to the main machine controller will also be
“lost” (voltage drops from 12v to 0v). In response, the main machine controller sets an oil pressure fault,
displays it on the control panel and immediately removes the power supply going out connector J3 pin
number 9 from the APECS 3000 Governor controller, which causes the engine to shut down.
Содержание CS7000 Fuel Cell EcoFlex
Страница 110: ...Electrical System 110 Service Manual CS7000 Electrical Panel Contactor Relay location Electrical Panel ...
Страница 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Страница 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Страница 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Страница 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Страница 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Страница 154: ...Service Manual CS7000 154 Electrical System 56509170 Rev L Sheet 8 of 9 Before SN 1000048160 Kubota LPG before LEV E4 ...
Страница 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Страница 172: ...Engine System LPG 172 Service Manual CS7000 Low LP Pressure Switch Fuel Tank Pressure relief valve Fuel Tank Area ...
Страница 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...