Dust Control/DustGuard
™
Systems
94
Service Manual – CS7000
Troubleshooting
Note:
You can use the Service Mode to toggle the various system components on and off to check for
function. Refer to the
Control System/Service Mode
section for information on how to enter
and use the Service Mode.
Problem
Cause
Correction
The DustGuard™
system does not
operate.
The DustGuard™ system
is not installed in the
configuration menu.
Make sure the DustGuard™ system is installed in the
configuration menu.
Inadequate water flow
to the DustGuard™
nozzles
Inadequate water level in
upper hopper
Check the water level.
The water strainer screen is
plugged.
Clean the strainer screen.
The water hoses/nozzles are
plugged.
Check and clean the water hoses/nozzles as
necessary.
The water solenoid valve is
plugged or not functioning
correctly.
Check for voltage at the solenoid valve.
•
If there is voltage at the solenoid, check the
solenoid coil resistance. It should measure 125
ohms ± 10%. If the coil resistance is not within
spec replace the solenoid valve.
•
If there is no voltage at the solenoid:
1.
Check the wiring and circuit breakers upstream
of the solenoid.
2. Check the
J3-13
output from A1 Main Machine
Controller.
The DustGuard™ pump (
M22
)
is not operating correctly.
Check for voltage at the pump.
•
If there is voltage at the pump, replace the pump.
•
If there is no voltage at the pump:
1.
Check the wiring and circuit breakers upstream
of the pump.
2. Check the
J3-13
output from A1 Main Machine
Controller.
Содержание CS7000 Fuel Cell EcoFlex
Страница 110: ...Electrical System 110 Service Manual CS7000 Electrical Panel Contactor Relay location Electrical Panel ...
Страница 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Страница 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Страница 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Страница 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Страница 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Страница 154: ...Service Manual CS7000 154 Electrical System 56509170 Rev L Sheet 8 of 9 Before SN 1000048160 Kubota LPG before LEV E4 ...
Страница 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Страница 172: ...Engine System LPG 172 Service Manual CS7000 Low LP Pressure Switch Fuel Tank Pressure relief valve Fuel Tank Area ...
Страница 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...