ELECTRICAL SYSTEM
SERVICE MANUAL
ENGLISH
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
909 6756 000(
5)2010-03
97
BATTERY TYPE SETTING (WET OR GEL) (For BA 451, BA 531, BA 551)
Set the electronic board of the machine and of the battery charger (if equipped) according to the type of batteries installed (WET or
GEL) as shown below:
Machine setting
Press the switch (71) or (73) and pay attention to the following in the very first seconds of machine operation:
1.
If the green warning led (81a) is flashing, the machine is set to GEL.
•
If the red warning led (81c) is flashing, the machine is set to WET.
•
If the setting is to be changed, perform the following procedure.
2.
Make sure that the switches (71) and (73) are turned off.
3.
Press and hold the switches (71) and (73) at the same time.
4.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
5.
Within three seconds, press the switch (73) again for a few seconds and check that the warning led for the required setting is
6.
flashing (as shown in step 1).
Battery charger setting (if equipped)
Remove the battery charger data inspection window screws (A).
7.
Remove the window (B).
8.
Turn the battery charger selector (C) to WET position for lead batteries, or to GEL position for gel batteries.
9.
Install the window (B) and tighten the screws (A).
10.
C
A
A
B
S301567