![Nilfisk-Advance CA 551 Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/nilfisk-advance/ca-551/ca-551_service-manual_1693245081.webp)
RECOVERY WATER SYSTEM
SERVICE MANUAL
ENGLISH
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
909 6756 000(
5)2010-03
79
VACUUM SYSTEM MOTOR CARBON BRUSH CHECK/REPLACEMENT (All models)
Remove the vacuum system motor (see the procedure in the relevant paragraph).
1.
At the workbench, remove the cover (A) (press-fitted) from the vacuum system motor (B).
2.
Remove the screws (C).
3.
Disconnect the electrical connections (D).
4.
Remove the carbon brushes (E).
5.
Check the carbon brushes for wear. Replace the carbon brushes when: the contact with the motor armature is insufficient, the
6.
carbon brushes are worn, the carbon brush contact surface is not integral, the thrust spring is broken, etc.
If necessary, replace the carbon brushes. Replace the carbon brushes as an assembly.
7.
Assemble the components in the reverse order of disassembly.
8.
S301555