FUSE CHECK/REPLACEMENT (For BA 451, BA 451D, BA 531, BA 531D, BA 551, BA 551D, BA 551CD,
BA 611D)
Disconnect the battery connector (12).
1.
Move aside the recovery water drain hose (16).
2.
Remove the battery charger cable (I), if equipped, from the cable holder (J).
3.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel
4.
(B).
Check/replace the following fuses:
5.
(C) - F1 fuse, deck: (40 A)
(D) - F2 fuse, vacuum system: (30 A)
(E) - F3 fuse, drive system: (30 A) (*)
(F) - F4 fuse, signal circuits: (3 A)
(G) - F5 fuse, brush/pad-holder release: (20 A) (*)
(H) - F6 fuse, pumps: (3 A) (*)
(*) Only for
BA 451D, BA 531D, BA 551D, BA 551CD, BA 611D
Perform steps 1 to 4 in the reverse order.