![Nilfisk-Advance CA 551 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/nilfisk-advance/ca-551/ca-551_service-manual_1693245074.webp)
RECOVERY WATER SYSTEM
ENGLISH
SERVICE MANUAL
72
909 6756 000(
5)2010-03
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
RECOVERY WATER SYSTEM
RECOVERY WATER TANK AND VACUUM GRID CLEANING, AND COVER GASKET CHECK (All
models)
Drive the machine to the appointed recovery water disposal area.
1.
- (For
2.
BA 451D, BA 531D, BA 551D, BA 551CD, BA 611D
) Turn the ignition key (80) to “0”.
- (For
BA 451, BA 531, BA 551
) Turn off the switches (71) and (73).
- (For
CA 451, CA 531, CA 551
) Disconnect the power supply cable (59) from the electrical mains.
Lift the cover (A) to washing position (L).
3.
Wash with clean water the cover (A), the tank (B) and the vacuum grid with automatic shut-off float (D).
4.
Drain the water in the tank through the hose (16).
5.
If necessary, release the fasteners (E) and open the grid (D), recover the float (F), clean all the components and then reinstall
them.
Check the tank cover gasket (G) for integrity.
6.
NOTE:
The hole (K), allowing to compensate the air in the cover interspaces, contributes to create vacuum in the tank.
If necessary replace the gasket (G) by removing it from its housing (H). When assembling the new gasket, install the joint (I) in
the rear central area, as shown in the figure.
Check that the bearing surface (J) of the gasket (G) is integral and adequate for the gasket itself.
7.
Check the compensation hole (K) for clogging, and clean it if necessary.
8.
NOTE:
The hole (K), allowing to compensate the air in the cover interspaces, contributes to create vacuum in the tank.
Close the cover (A).
9.
NOTE:
Figure showing
BA 551CD
H
D
E
E
F
G
I
L
K
G
A
B
J
S301551