ECOFLEX™ SYSTEM
ENGLISH
SERVICE MANUAL
38
909 6756 000(
5)2010-03
BA 451 / BA 451D / BA 531 / BA 531D / BA 551 / BA 551D / BA 551CD / BA 611D
CA 451 / CA 531 / CA 551
WATER PUMP DISASSEMBLY/ASSEMBLY (For BA 451D, BA 531D, BA 551D, BA 551CD, BA 611D)
Disassembly
If the tank (21) contains recovery water:
1.
Drive the machine to the appointed recovery water disposal area.
•
Turn the ignition key (80) to “0”.
•
Empty the recovery water tank (21) with the hose (16).
•
Drive the machine on a level floor.
2.
Turn the ignition key (80) to “0”.
3.
Grasp the handle (41) and carefully lift the tank (40).
4.
Disconnect the connector (A).
5.
Loosen the clamps (B) and disconnect the hoses (C) from the water pump (D).
6.
Remove the screws (E).
7.
Remove the water pump (D).
8.
Assembly
Assemble the components in the reverse order of disassembly.
9.
NOTE:
Figure showing
BA 551D
,
BA 551CD
,
BA 611D
B
C
E
D
E
A
C
B
S301526