lectrical S ste
Service Manual – SC8000
Pin
ID
Desig
Pin Assignment
Signal
Nominal
Voltage at
Connector
when
activated
Ref,
To
Load or Supply
Characteristics
Comments
J3-10
Ground
J3-11
Ground
Ground
Ground
0V
B-
Ground
J3-12
Ground
Ground
Ground
0V
B-
Ground
J3-13
Ground
Ground
Ground
0V
B-
Ground
J3-14
Power
(B+)
Circuit Breaker2
(VACC2)
Power
12 - 15 VDC
B-
System voltage
Power from circuit breaker 2 (20A)
J3-15
Power
(B+)
Circuit Breaker 2
(VACC2)
Power
12 - 15 VDC
B-
System voltage
Power from circuit breaker 2 (20A)
J3-16
Power
(B+)
Circuit Breaker 3
(VACC3)
Power
12 - 15 VDC
B-
System voltage
Power from circuit breaker 3 (15A)
J3-17
Output
Horn
Low side
driver
0V
B-
Electromagnetic
horn 4A @12V
J3-18
Output
Side Sweep Mist
Pump
Low side
driver
0V
B-
Pump motor 3.9
FLA @ 24V, 16
LRA
24V pump operated at 12V
J3-19
Output
Detergent Pump 2 (-)
H-bridge
driver
0 to B+
B-
0.65A @ 12V
Pulsed on and off at a rate less than 10 Hz
J3-20
Output
Detergent Pump 2 (+)
H-bridge
driver
0 to B+
B-
0.65A @ 12V
Pulsed on and off at a rate less than 10 Hz
J3-21
Output
Detergent Pump 1 (-)
H-bridge
driver
0 to B+
B-
0.65A @ 12V
Pulsed on and off at a rate less than 10 Hz
J3-22
Output
Detergent Pump 1 (+)
H-bridge
driver
0 to B+
B-
0.65A @ 12V
Pulsed on and off at a rate less than 10 Hz
J3-23
Output
Wand Solution Pump
Low side
driver
0V
B-
Pump motor 12.5
FLA@12V, 50
LRA
Содержание 56108110 SC8000 48 LPG
Страница 17: ...eneral n or ation Service Manual SC8000 verall i ensions ...
Страница 80: ...irin ia ra u ota n ine 0 lectrical S ste 80 Service Manual SC8000 ...
Страница 110: ...raulic S ste 0 Service Manual SC8000 raulic Sc e atic ...
Страница 123: ...raulic S ste Service Manual SC8000 S ecial ools Hydraulic test gauge w connector 3000 psi range p n 56504516 ...
Страница 150: ...Scru S ste C lin rical 0 Service Manual SC8000 S ecial ools GUDXOLF WHVW JDXJH Z FRQQHFWRU SVL UDQJH S Q ...
Страница 225: ......