S uee ee S ste
Service Manual – SC8000
acuu an
an S uee ee
The following conditions must be met for the Vacuum Fan to shut off and for the squeegee to be raised to the
travel position:
The
Key Switch
must be on.
The engine must be running.
The scrub off mode must be selected or the vacuum system switched off at the
Dashboard Panel
, or the
drive pedal must be moved to the reverse position (squeegee will rise up).
The Vacuum Fan will shut off after a time delay once the drive pedal is in the neutral position. Note that
if the seat switch is open, the Vacuum Fan will run continuously (regardless of the drive pedal being in
neutral) to allow water pick-up with the Wand attachment.
Component
Current - Amps
Coil Resistance - Ohms
L3
1.5 Amps
8 ohms
L2
B-
B+ from
K1 Power Relay
B- OUTPUT
TOUCH PAD
DASHBOARD PANEL
L1
B+
CB5
10A
GRN/BRN
B-
RED/VIO
DRIVER BOX
PIN J2-6
L3
SQUEEGEE
UP SOLENOID
BRN/GRN
SQUEEGEE
DOWN
VACUUM FAN
S1
KEY SWITCH
1
12
Содержание 56108110 SC8000 48 LPG