![Nidec POWERDRIVE FX 100T Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/nidec/powerdrive-fx-100t/powerdrive-fx-100t_installation-manual_1687880021.webp)
21
CONNECTIONS
POWERDRIVE FX Installation guide
4729 en - 2017.08 / c
3.2.3 -
Factory configuration of control
terminal blocks
Note:
For details of the parameters, refer to the commissioning
manual ref.4617.
+10V ref
AI1+
AI1-
AI2+
AI2-
0V
COM-RL1
RL1
COM-RL2
RL2
AO1
AI3
+24V ref
DO1
STO-1
DI2
DI3
STO-2
DI5
DI4
+24V ref
1
2
3
4
5
6
1
2
3
4
8
7
0V
DI1/CTP
10
9
1
2
3
4
5
6
8
7
9
Référence
vitesse 4-20mA
CTP moteur*
Relais d’état du
variateur (N/O)**
Relais alarme
vitesse maximum
Image courant
4-20 mA
Vitesse nulle
Sélection référence
Sélection référence
Marche AV/arrêt
Marche AR/arrêt
Absence sûre du couple/
Entrée déverrouillage 1
Absence sûre du couple/
Entrée déverrouillage 2
PX1
PX2
PX3
Référence
vitesse 0-10V
Note:
This configuration has been obtained from a drive with factory
settings (default parameter settings).
The STO-1 and STO-2 inputs must be closed before giving a
run command.
(*) By default, the motor sensor detection is disabled. If the
motor thermal sensor needs to be connected to DI1/CTP, set
Mtr.06 (05.70)
= Drive terminal (1).
(**) RL1 relay opens when at least one of the STO is open.
• Modification of the Run/Stop control logic
- For «3-wire» control (job Run/Stop) :
DI4
DI5
+24V ref
Marche AV
Arrêt
7
8
9
List of parameters to set:
Ctr.06 (06.04)
= Run latched (1),
I/O.10 (08.25)
=
06.39
Stop sequencing bit
(DI5 terminal)
- For Run/Stop control with change of direction:
DI4
DI5
+24V ref
Marche/Arrêt
Inversion
de sens
7
9
8
List of parameters to set:
Ctr.06 (06.04)
= Run-Fwd/Rev (2),
I/O.09 (08.24)
=
06.34
Run/Stop sequencing bit
(DI4 terminal)
I/O.10 (08.25)
=
06.33
FWD/Reverse sequencing bit
(DI5 terminal)
• Selection of the reference via digital inputs
DI2
DI3
Selection
0
0
Voltage speed reference (0-10 V) on
analog input AI1+, AI1-
0
1
Current speed reference (4-20 mA) on
analog input AI2+, AI2-
1
0
Preset reference 2 (RP2)
Spd.05 (01.22)
to be set
1
1
Содержание POWERDRIVE FX 100T
Страница 1: ...POWERDRIVE FX Installation guide 4 quadrant Variable speed drive Part number 4729 en 2017 08 c...
Страница 9: ...9 GENERAL INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...
Страница 15: ...15 MECHANICAL INSTALLATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...
Страница 37: ...37 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...
Страница 38: ...38 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...
Страница 39: ......