![Nidec POWERDRIVE FX 100T Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/nidec/powerdrive-fx-100t/powerdrive-fx-100t_installation-manual_1687880012.webp)
12
MECHANICAL INSTALLATION
POWERDRIVE FX Installation guide
4729 en - 2017.08 / c
2.2.2 - Through-panel mounting
CAUTION:
To obtain IP54 protection at the back of the heatsink, an additional seal is needed (not supplied, adhesive strip of EPDM
rubber or equivalent).
The
POWERDRIVE FX
is delivered with its fixing feed mounted, ready for surface mounting. For through-panel mounting, remove
the feet, and follow the instructions below.
2.2.2.1 - Ratings 33T to 50T
530
200
18
495
Ø
553
486
140*
15
Ø
> 40
231
for M6 crimp
cap nuts
Lifting rings
Solid
surface
Back of
the cabinet
seal
seal
Drill hole diagram
Side view
85.5
15.5
Dimensions in mm
(*)
•
With MDX-I/O M2M option, add +25mm
•
With MDX-ENCODER, MDX-RESOLVER, MDX-I/O Lite
or MDX-Fieldbus option, add +30mm
(the 2 option types can be combined, add +55mm)