4
These are the most important operations, designed to guarantee the
maximum safety of the automation system. The testing procedure
can also be used as a periodic check of the devices that make up
the automation. The testing of the automation system must be per-
formed by qualified and experienced personnel who must establish
what tests should be conducted based on the risk involved, and ver-
ify the compliance of the system with applicable regulations, legisla-
tion and standards, in particular with all the provisions of EN stan-
dard 12445 which establishes the test methods for gate automation
systems.
4) Testing and commissioning
The maintenance operations must be performed in strict compliance
with the safety directions provided in this manual and according to
the applicable legislation and standards. POP does not require any
special maintenance. However, periodically make sure (at least once
every six months) that all the devices are perfectly efficient.
To this end, carry out all the tests and checks described in para-
graph 4.1 “Testing”. If other devices are present, follow the directions
provided in the corresponding maintenance schedule.
5) Maintenance
5.1) Disposal
POP is constructed of various types of materials, some of which can
be recycled (aluminium, plastic, electric cables), while others must
be disposed of (electronic boards).
WARNING: some electronic components may contain
polluting substances; do not pollute the environment.
Enquire about the recycling or disposal systems available
in compliance with regulations locally in force.
1.
Disconnect the automation system from the electric mains.
2.
Disassemble all the devices and accessories, following in reverse
order the procedures described in chapter 2 “Installation”.
3.
Remove the electronic board.
4.
Sort the various electrical and recyclable materials and consign
them to licensed firms for recovery and disposal.
5.
Consign the remaining materials to authorized scrap collection
centres.
!
4.1) Testing
1.
Make sure that the provisions contained in the chapter “WARN-
INGS” have been carefully observed.
2.
Test the opening and closing of the gate and make sure that the
leaves move in the intended direction. The test should be carried
out a number of times to make sure that the gate moves smooth-
ly, that there are no points of excessive friction and that there are
no defects in the assembly or adjustments.
3.
Check the proper operation of all the safety devices, one by one.
4.
Measure the impact force according to EN standard 12445.
If “motor force” control is used to assist the system for the reduc-
tion of the impact force, try to find the adjustment that gives the
best results.
6) Technical characteristics
Power supply
Vac/Hz
230/50
120/50-60
/
Vdc
/
/
24
Max. current
A
~1
~2
3
Motor power
W
75
Torque Nm
180
Opening time
s
10
Operating temperature
°C
-20°÷50°
Protection class
IP 44
Work cycle
30%
Insulation class
1
B
*
This version does not have a control unit.
PP7024
PP7024/V1
PP7224*
KIO - Key-operated selector switch with cord-type release