2
Warnings:
The MINDY A02 control unit has been designed for the control of a sin-
gle-phase asynchronous motor used for the automation of shutters,
overhead garage doors, gates, rolling shutters or awnings.
Any other use is improper and prohibited. The motors must be equipped
with electromechanical limit switches designed to limit their movement.
Keep in mind that these automation systems must be installed by qual-
ified personnel in compliance with current laws and regulations.
The Mindy A02 control unit enables the control of single-phase asynchronous motors powered by the electrical mains, with “COMMON” “OPEN”
“CLOSE” type connections. It is designed for the automation of shutters, overhead garage doors, gates, rolling shutters or awnings. The control
unit incorporates a radio receiver operating at a frequency of 433.92 MHz, which is compatible with the following types of transmitters:
The control unit is equipped with a number of inputs used to activate commands such as “step-by-step”, “open”, “close”, as well as signals
for the triggering of safety devices such as photocells or stop commands. The control unit can be connected to TTBUS systems.
1) Product description
2) Installation
The electrical systems and the automations must be
installed by qualified and experienced personnel in com-
pliance with current legislation. Before you proceed to
make any connections make sure that the mains power
supply is disconnected.
To proceed with the installation, secure the container as shown in fig-
ure 1. When you drill a hole in the container for installation and wiring,
take the necessary precautions to guarantee the required IP protec-
tion class. The wires must always be threaded from below.
!
1
T1
T2
C
FLASH
L
+24Vcc
N
P.P.
PHOTO
STOP
M
A
B
C
E
D
F
L
I
H
G
N
O
P
A
Line fuse (5A)
B
“close” relay
C
“open” relay
D
low voltage transformer
E
microprocessor
F
connector for SMU programmer
G
programming dip-switch
H
“radio” LED
I
“radio” pushbutton
L
“stop”, “photo” and “step-by-step” inputs LED
M
terminal for radio aerial
N
“step by step” pushbutton
O
low voltage input terminals
P
line, motor and flashing light connection terminals
Coding
TX Line
Transmitters
FLO
FLO
FLO1, FLO2, FLO4
VERY
VERY VE
NICE WAY
WM080G, WM240C (code C)
FLOR
FLOR
FLO1R, FLO2R, FLO4R
VERY
VERY VR
ERGO
ERGO1, ERGO4, ERGO6
PLANO
PLANO1, PLANO4, PLANO6, PLANOTIME
NICE WAY
TUTTA LA LINEA; WM080G, WM240C (code A or B)
SMILO
SMILO
SM2, SM4
NICE WAY
WM080G, WM240C (code D)
Table “A1”
As the type of coding is different, the first transmitter mem-
orized also determines the type of transmitters that may be
memorized later, see “code” in table A1.
Up to 254 transmitters can be memorized.
The management of the radio transmitters is made easier
by the SMU, TTP or TTI programming units.
After each command, the motor is powered for the set
“working time” and programmed during the installation
stage. The limit switch incorporated in the motor stops the
movement when the desired position is reached. The
“pause time” can be programmed after which automatic
closure occurs.
Содержание MINDY A01