background image

English – 

1

EN

ENGLISH

User manual translated from the German 

these user instructions cover R01 series units

(see nameplate).

CONTENTS

 .......................................................................................

Page

GENERAL SAFETY PRECAUTIONS ...............................................................1
BASIC DESCRIPTION AND PREPARING THE INSTALLATION........................1
ASSEMBLING THE D-PRO AUTOMATIC CONTROL UNIT .............................2
HOOKING UP THE MAINS CABLE .................................................................3
CONTROLS AND CONNECTIONS .................................................................4
ADJUSTING THE MECHANICAL LIMIT SWITCHES ........................................5 
ADJUSTING THE DIGITAL LIMIT SWITCHES ..................................................6
OPERATING FUNCTIONS ..............................................................................7
D-PRO AUTOMATIC 2.2 kW SCHEMATIC DIAGRAM .....................................8
D-PRO AUTOMATIC 2.2 kW MOTHERBOARD ...............................................9
D-PRO AUTOMATIC 2.2 kW FRONT BOARD ...............................................10
TECHNICAL DATA - SPECIFICATIONS .........................................................11
DECLARATION OF CONFORMITY ...............................................................11                     

GENERAL SAFETY PRECAUTIONS

D-PRO Automatic door control units are conforming with established safety 

legislation, as are the contents of this manual. Incorrect installation can result 

in serious injury to the installers and users. For this reason, during installation, 

always strictly observe all instructions in this manual.

Do not proceed with the installation if anything is unclear to you; contact 

Nice customer service for support.

WORK SAFELY!

CAUTION! – These instructions are critical to your safety.
CAUTION! – Keep the important safety instructions.
Observe the following instructions in full:

 Only  make  the  electrical  hookup  specified  in  this  manual;  improper

hookup can serious damage the system.

 If used outdoors, the cables must be completely protected by plastic

cable ducting.

Given the risks attendant on the installation and use of the system, the 

propulsion system installation must satisfy the following requirements:

- only make the modifications given in these instructions to the control unit and 

drive. Any other modifications may result in damage. The manufacturer is not 

liable for damage caused by arbitrary modifications to the propulsion system 

or control unit;

- make sure the control units are out of the reach of sources of heat and open 

flames at all times. Failure to do so may result in damage, fire and other hazards;
- do not immerse the control unit or drive in water or other fluids during their 

installation. Do not allow fluids to enter the system during the installation;
- the propulsion system's packaging must be disposed of in accordance with 

local regulations.

CAUTION!

 – Keep these instructions carefully as a reference for scrapping and 

servicing the equipment.

BASIC DESCRIPTION AND PREPARING THE 

INSTALLATION

Description and use

The D-PRO Automatic is a control unit for three-phase and single-phase drives 

for  sectional,  rapid  and  roller  doors,  running  on  230  and  400V  power,  with 

mechanical or electronic limit switches. It is compatible with all usual safety and 

control devices.
Other  possible  applications  (traffic  lights,  inductive  loops  for  recognising 

vehicles  or  remote  service  functions)  can  be  implemented  by  inserting  other 

boards (modules).
To  open  or  close  a  door,  simply  press  the  button  on  the  housing  or  the 

corresponding external button.
In automatic mode, the door can be also be opened closed by radio.

Any other use is non-conforming! The manufacturer is not responsible 

for damage resulting from non-conforming use of the system's 

equipment not specified in these instructions.

The  manufacturer  is  responsible  for  the  entire  system  and  must  ensure 

observance  of  the  applicable  standards  and  directives  (including  EN  13241-

1). The manufacturer must ensure that the EMC, Low Voltage, Machinery and 

Construction Products directives are observed.
He is responsible for providing the technical documentation for the system as a 

whole, which must be enclosed with the system itself.

National and local regulations governing the installation must be 

observed, as well as any national accident prevention legislation. 

When working on the installation, the door system must be disconnected from 

its power supply.

Pre-installation controls

Before starting the installation of the control unit, carefully read these installation 

and user instructions in full. 
The manufacturer is not liable for any responsibility or guarantee relating to the 

product if the system is modified without his written authorisation in advance, 

or non-conforming installations in violation of the installation instructions are 

done or permitted. 
The  manufacturer  must  ensure  that  the  EMC,  Low  Voltage,  Machinery  and 

Construction Products directives are observed.

CAUTION! - The control unit and drive may not be used in potentially 

explosive environments.

Содержание D-Pro Automatic R01 Series

Страница 1: ...inal operating instructions in German these operating instructions cover series R01 devices see nameplate Control unit Industrial D Pro Automatic IS0040F00MM_20 12 2016 www niceforyou com Nice S p A V...

Страница 2: ......

Страница 3: ...ing the installation the propulsion system s packaging must be disposed of in accordance with local regulations CAUTION Keep these instructions carefully as a reference for scrapping and servicing the...

Страница 4: ...03 The mounting of the housing will depend on the conditions in the installation location It may be installed in one of 3 ways a directly onto the wall using the bolts on the housing A b using the pro...

Страница 5: ...ch In this case the SCHUKO connector may be removed during the installation If using a 200V DC brake L2 N must be connected to N on terminal X1 Functions and parameters The D Pro Automatic control uni...

Страница 6: ...ULSE STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 Connection of 3 x button with 4 wire cable STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 Connection of a key switch STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 7 Hookin...

Страница 7: ...2 If a drive with electronic limit switches is hooked up further bridges will be required in positions J26 J27 of terminal X7 All these bridges and jumpers are installed in the factory Hooking up the...

Страница 8: ...he D PRO Automatic parameters and error list addendum accompanying this manual ADJUSTING THE DIGITAL LIMIT SWITCHES Adjusting the end positions To this end set dipswitch 4 to ON ON 1 SAB 2 3 4 The upp...

Страница 9: ...1 sec The value changes by 10 units sec Hold the button down for 3 sec The value changes by 100 units sec Automatic Closing If the automatic close function is enabled the door closes after the time se...

Страница 10: ...8 English EN Schematic overview D PRO Automatic 2 2kW...

Страница 11: ...ke Starter condenser board connector Motor terminals PE terminals Select lower sensitive edge Controller board Sensitive edge terminal clamps Mains terminals Transit photocell terminal clamps Key swit...

Страница 12: ...10 English EN Front board D PRO Automatic 2 2kW Dipswitch CLOSE button OPEN button Controller board cable D PRO housing front view front board with display...

Страница 13: ...PRO AUTOMATIC 2 2kW D PRO AUTOMATIC 5 5kW Power supply 3 x 400V AC 50Hz protected by 6 10A fuse 3 x 400V AC 50Hz protected by 10A fuse Motor power up to 2 2kW up to 5 5kW Motor connection 3 NO contac...

Страница 14: ......

Страница 15: ......

Страница 16: ...11 20 5 2 2 5 5 10 6 50 400 3 10 50 400 3 2 2 5 5 3 3 2 2 400 5 5 400 AT 6 3 4 4 50 20 50 20 0 8 24...

Страница 17: ...10 2 2 CLOSE CLOSE...

Страница 18: ...9 2 2 OXI 200 PE 2 1 N O N O N O N C TYKO Mini Fit...

Страница 19: ...8 2 2...

Страница 20: ...7 DIP OFF ON 1 0 ON 4 1 ON 4 1 ON 1 0 ON 1 ON 4 1 4 OFF ON 4 1 10 100 3 41 OPEN EE 1 P70 0 P5 1 P5 2 P5 1 P29 CLOSE CLOSE...

Страница 21: ...X7 MiniFit AMP 3 X7 MiniFit AMP 4 X7 MiniFit AMP 2 X7 MiniFit AMP 5 X7 MiniFit AMP 6 X7 MiniFit AMP 1 CLOSED 3 E OPEN 1 E 4 SE 2 SE 4 SE 2 SE 7 P2 8 P2 5 P1 6 P1 6 5 16 dip 4 ON SAB OFF 4 4 ON OFF 4...

Страница 22: ...led OXI 106 14 J10 X2 J15 X4 J31 X5 J33 X6 6 5 X8 2 1 X9 X7 J27 J26 MLT ML 230 MLT ML 7 X3 X1 L1 9 X3 X1 N ML ML T N L1 L2 L3 X1 X3 15 X1 230 MLT ML 6 105 2 7 2 6 5 4 3 2 1 2 8 2 7 1 6 1 5 4 3 2 1 P2...

Страница 23: ...PEN OPEN STOP X4 X4 J15 X4 J15 J16 J17 J18 3X X4 J15 J16 J17 J18 X4 J15 J16 J17 J18 7 kOhm 8 2k l opto 8 2k l opto X 5 X 5 8 Opto J1 J27 X7 5 X6 GND 0V SIG output 12VDC 9 8 2 X6 SIG NDA010 X6 10 8 2 X...

Страница 24: ...2 0 25 2 3 10 4 5 1 X1 L3 N L2 L1 PE 3 PE N L3 L2 L1 16 CEE CEE EP N L3 L2 L1 X1 16 3 PE X1 N L2 L1 4 PE L2 L1 SCHUKO 200 SCHUKO X1 N L2 N 50 CEE 2 P 75 75 L3 N 2 PE V U W B D A L2 L1 V W U C L3 N L2...

Страница 25: ...2 01 02 03 2 4 NDA530 20 04 1 4 2...

Страница 26: ...1 R01 1 1 2 3 4 5 6 7 8 2 2 9 2 2 10 2 2 11 11 D PRO 400 230 13241 1...

Страница 27: ......

Страница 28: ...utomatic IS0040F00MM_20 12 2016 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com Original operating instructions in German these operating instructions cover s...

Отзывы: