background image

English – 

11

EN

TECHNICAL DATA - SPECIFICATIONS

Notes

• All the technical characteristics refer to a temperature of 20°C (±5°C).

• Nice reserves the right to modify the product at its own discretion while maintaining its function and intended use.

• The full user instructions are composed of the drive user instructions and the user instructions for the associated control unit.

DESCRIPTION

D-PRO AUTOMATIC - 2.2kW

D-PRO AUTOMATIC - 5.5kW

Power supply

3 x 400V AC 50Hz (protected by 6 / 10A fuse)

3 x 400V AC 50Hz (protected by 10A fuse)

Motor power

 up to 2.2kW

 up to 5.5kW

Motor connection

3 NO contactor contacts

3 NO contactor contacts

400V/max. 2.2 kVA

400V/max. 5.5kVA

Protection in both cases: 6.3 AT ceramic fuse with self-extinguishing material CAUTION: only the provided ceramic 

fuses may be used for the motor protection.

Standby power

< 4VA

< 4VA

Ambient temperature

 from -20°C to +50°C

 from -20°C to +50°C

Control voltage 

24 V DC secondary protection with delayed action 0.8A fuse

Содержание D-Pro Automatic R01 Series

Страница 1: ...inal operating instructions in German these operating instructions cover series R01 devices see nameplate Control unit Industrial D Pro Automatic IS0040F00MM_20 12 2016 www niceforyou com Nice S p A V...

Страница 2: ......

Страница 3: ...ing the installation the propulsion system s packaging must be disposed of in accordance with local regulations CAUTION Keep these instructions carefully as a reference for scrapping and servicing the...

Страница 4: ...03 The mounting of the housing will depend on the conditions in the installation location It may be installed in one of 3 ways a directly onto the wall using the bolts on the housing A b using the pro...

Страница 5: ...ch In this case the SCHUKO connector may be removed during the installation If using a 200V DC brake L2 N must be connected to N on terminal X1 Functions and parameters The D Pro Automatic control uni...

Страница 6: ...ULSE STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 Connection of 3 x button with 4 wire cable STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 Connection of a key switch STOP OPEN Imp CLOSE X4 J15 J16 J17 J18 7 Hookin...

Страница 7: ...2 If a drive with electronic limit switches is hooked up further bridges will be required in positions J26 J27 of terminal X7 All these bridges and jumpers are installed in the factory Hooking up the...

Страница 8: ...he D PRO Automatic parameters and error list addendum accompanying this manual ADJUSTING THE DIGITAL LIMIT SWITCHES Adjusting the end positions To this end set dipswitch 4 to ON ON 1 SAB 2 3 4 The upp...

Страница 9: ...1 sec The value changes by 10 units sec Hold the button down for 3 sec The value changes by 100 units sec Automatic Closing If the automatic close function is enabled the door closes after the time se...

Страница 10: ...8 English EN Schematic overview D PRO Automatic 2 2kW...

Страница 11: ...ke Starter condenser board connector Motor terminals PE terminals Select lower sensitive edge Controller board Sensitive edge terminal clamps Mains terminals Transit photocell terminal clamps Key swit...

Страница 12: ...10 English EN Front board D PRO Automatic 2 2kW Dipswitch CLOSE button OPEN button Controller board cable D PRO housing front view front board with display...

Страница 13: ...PRO AUTOMATIC 2 2kW D PRO AUTOMATIC 5 5kW Power supply 3 x 400V AC 50Hz protected by 6 10A fuse 3 x 400V AC 50Hz protected by 10A fuse Motor power up to 2 2kW up to 5 5kW Motor connection 3 NO contac...

Страница 14: ......

Страница 15: ......

Страница 16: ...11 20 5 2 2 5 5 10 6 50 400 3 10 50 400 3 2 2 5 5 3 3 2 2 400 5 5 400 AT 6 3 4 4 50 20 50 20 0 8 24...

Страница 17: ...10 2 2 CLOSE CLOSE...

Страница 18: ...9 2 2 OXI 200 PE 2 1 N O N O N O N C TYKO Mini Fit...

Страница 19: ...8 2 2...

Страница 20: ...7 DIP OFF ON 1 0 ON 4 1 ON 4 1 ON 1 0 ON 1 ON 4 1 4 OFF ON 4 1 10 100 3 41 OPEN EE 1 P70 0 P5 1 P5 2 P5 1 P29 CLOSE CLOSE...

Страница 21: ...X7 MiniFit AMP 3 X7 MiniFit AMP 4 X7 MiniFit AMP 2 X7 MiniFit AMP 5 X7 MiniFit AMP 6 X7 MiniFit AMP 1 CLOSED 3 E OPEN 1 E 4 SE 2 SE 4 SE 2 SE 7 P2 8 P2 5 P1 6 P1 6 5 16 dip 4 ON SAB OFF 4 4 ON OFF 4...

Страница 22: ...led OXI 106 14 J10 X2 J15 X4 J31 X5 J33 X6 6 5 X8 2 1 X9 X7 J27 J26 MLT ML 230 MLT ML 7 X3 X1 L1 9 X3 X1 N ML ML T N L1 L2 L3 X1 X3 15 X1 230 MLT ML 6 105 2 7 2 6 5 4 3 2 1 2 8 2 7 1 6 1 5 4 3 2 1 P2...

Страница 23: ...PEN OPEN STOP X4 X4 J15 X4 J15 J16 J17 J18 3X X4 J15 J16 J17 J18 X4 J15 J16 J17 J18 7 kOhm 8 2k l opto 8 2k l opto X 5 X 5 8 Opto J1 J27 X7 5 X6 GND 0V SIG output 12VDC 9 8 2 X6 SIG NDA010 X6 10 8 2 X...

Страница 24: ...2 0 25 2 3 10 4 5 1 X1 L3 N L2 L1 PE 3 PE N L3 L2 L1 16 CEE CEE EP N L3 L2 L1 X1 16 3 PE X1 N L2 L1 4 PE L2 L1 SCHUKO 200 SCHUKO X1 N L2 N 50 CEE 2 P 75 75 L3 N 2 PE V U W B D A L2 L1 V W U C L3 N L2...

Страница 25: ...2 01 02 03 2 4 NDA530 20 04 1 4 2...

Страница 26: ...1 R01 1 1 2 3 4 5 6 7 8 2 2 9 2 2 10 2 2 11 11 D PRO 400 230 13241 1...

Страница 27: ......

Страница 28: ...utomatic IS0040F00MM_20 12 2016 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com Original operating instructions in German these operating instructions cover s...

Отзывы: