Settings
6
EVC 13
The indoor temperature depends on several factors.
During the hot season, solar radiation and heat given
off by people and equipment are sufficient to keep the
house warm. When it gets colder outside, the heating
system must be started. The colder its gets, the hotter
the radiators must be.
This adjustment is made automatically, however the
basic settings must first be made on the boiler (see
below).
The basic heating is set with the Heating curve selec-
tion knob and with the Offset heating curve knob.
If you do not know the correct settings use the basic da-
ta from the map opposite. If the required room tempera-
ture is not obtained, readjustment may be necessary.
NOTE!
Wait one day between settings so that the tem-
peratures have time to stabilise.
Readjustment of basic settings.
Cold weather conditions
If the room temperature is low, increase the heating
curve selection setting by one step.
If the room temperature is high, reduce the heating
curve selection setting by one step.
Warm weather conditions
If the room temperature is low, turn the Offset heat-
ing curve knob one step clockwise.
If the room temperature is high, turn the Offset heat-
ing curve knob one step anticlockwise.
Default setting
Heating control system
Heating curve
selection
Offset heating
curve
Night change
Содержание EVC 13