System description
3
GT1
Outdoor sensor
GT2
Boiler/flow sensor
SÄV
Safety valve boiler
EXP
Expansion vessel
AV1
Tapping valve
AV2 *
Shut-off valve radiator circuit
flow
AV3 *
Shut-off valve radiator circuit
return
AV4
Filling valve
AV7
Pressure controlled bypass
valve
CP
Circulation pump
EP
Immersion heater
RC
Automatic heating control
system
UR
Timer
K2 *
Contactor tariff control of the
electric water heater
BR *
Tariff control bypass
SÄK *
Miniature circuit-breaker group
RAD *
Radiator circuit
*
Not included in the standard
delivery
Principle of operation
EVC 13 has an outdoor temperature controlled boiler
temperature which is why a shunt valve is not re-
quired. The outside temperature sensor is supplied.
The output is connected and disconnected with the
help of two contactors and two relays. EVC 13 has an
integrated circulation pump, expansion vessel, safety
valve, tapping valve, load monitor and an input for
centralised load control. Current regulations require
the heating installation to be inspected before it is
commissioned. The inspection must be carried out by
a suitably qualified person and should be document-
ed. The above applies to electric boilers with a closed
expansion vessel. The installation must be inspected
again if the boiler or the expansion vessel are re-
placed.
RAD*
P
GT1
SÄV
GT2
CP
RC
Till VVB
EXP
AV1
AV3*
AV2*
EP
UR
Matning
EVC 13
Från tariffur
K2*
BR*
SÄK*
Utrustning för matning av yttre elvattenvärmare (tillbehör)
AV7
AV4
General
EVC 13
From the tariff timer.
Equipment for powering an external electrical hot
water heater (accessory).
Supply